{"title":"对废水处理应用的鲁棒控制","authors":"Manhal Abouzlam, R. Ouvrard, D. Mehdi, Florence Pontlevoy, B. Gombert, N. Karpel Vel Leitner, Sahidou O. B. Boukari","doi":"10.1109/ICOSC.2013.6750865","DOIUrl":null,"url":null,"abstract":"This paper deals with the control of a wastewater treatment pilot by catalytic ozonation. In general, catalytic ozonation processes operate with a deliberate ozone overproduction to obtain a treated water which respects the discharge standards. But, in this case, the oxygen consumption is not optimal and the operating costs are important. The objective of this study focuses on the optimization of the catalytic ozonation pilot. An optimal control is proposed to obtain a significant abatement of the pollutant. In this application, the pollutant abatement is represented by the absorbance.","PeriodicalId":199135,"journal":{"name":"3rd International Conference on Systems and Control","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A robust control for wastewater treatment application\",\"authors\":\"Manhal Abouzlam, R. Ouvrard, D. Mehdi, Florence Pontlevoy, B. Gombert, N. Karpel Vel Leitner, Sahidou O. B. Boukari\",\"doi\":\"10.1109/ICOSC.2013.6750865\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the control of a wastewater treatment pilot by catalytic ozonation. In general, catalytic ozonation processes operate with a deliberate ozone overproduction to obtain a treated water which respects the discharge standards. But, in this case, the oxygen consumption is not optimal and the operating costs are important. The objective of this study focuses on the optimization of the catalytic ozonation pilot. An optimal control is proposed to obtain a significant abatement of the pollutant. In this application, the pollutant abatement is represented by the absorbance.\",\"PeriodicalId\":199135,\"journal\":{\"name\":\"3rd International Conference on Systems and Control\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"3rd International Conference on Systems and Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICOSC.2013.6750865\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"3rd International Conference on Systems and Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOSC.2013.6750865","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文研究了催化臭氧化处理废水中试的控制。一般来说,催化臭氧化过程是在臭氧过量生产的情况下进行的,以获得符合排放标准的处理水。但是,在这种情况下,氧气消耗不是最优的,运行成本很重要。本研究的目的是对催化臭氧化试验装置进行优化。提出了一种最优控制方法,以获得污染物的显著减少。在这种应用中,污染物的减少是用吸光度来表示的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A robust control for wastewater treatment application
This paper deals with the control of a wastewater treatment pilot by catalytic ozonation. In general, catalytic ozonation processes operate with a deliberate ozone overproduction to obtain a treated water which respects the discharge standards. But, in this case, the oxygen consumption is not optimal and the operating costs are important. The objective of this study focuses on the optimization of the catalytic ozonation pilot. An optimal control is proposed to obtain a significant abatement of the pollutant. In this application, the pollutant abatement is represented by the absorbance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Robust nonlinear control design for turbocharged biodiesel engine Observability-singularity manifolds in the context of chaos based cryptography Design of unbiased functional observers for interconnected discrete-time delay systems H∞ filter based-controller for a class of continuous time nonlinear singular systems From restricted isometry property to observability under sparse measurement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1