{"title":"一种同时补偿单相牵引系统谐波和负载不平衡的混合有源滤波器拓扑","authors":"B. Gholizad, M. Akhbari","doi":"10.1109/POWERENG.2011.6036545","DOIUrl":null,"url":null,"abstract":"Electrified Traction systems cause power quality problems in their power supply system. This is mainly due to the power electronic converters of traction system drives and their single phase operation. The created harmonics and unbalance currents are propagated in the upstream electrical network. Also, the created harmonics put the power quality of the traction system in danger. In this paper the traction system load is characterized, an algorithm for compensating simultaneously the both harmonics and load unbalances, and a topology of Hybrid Active Power Filter (HAFP) for improving of power quality in upstream network and the traction system is presented. The proposed algorithm can be adapted to any traction transformer connections / configurations. Besides, the load side compensation is used which reduces the cost of installations. And the proposed topology caused reducing the size of the Active Power Filter (APF). The topology is successfully tested under normal operation and load change conditions. The simulation results show the good performance of the algorithm under non-stiff supply network as well.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A topology of Hybrid Active Power Filter for simultaneously compensating harmonics and load unbalance in single phase traction systems\",\"authors\":\"B. Gholizad, M. Akhbari\",\"doi\":\"10.1109/POWERENG.2011.6036545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrified Traction systems cause power quality problems in their power supply system. This is mainly due to the power electronic converters of traction system drives and their single phase operation. The created harmonics and unbalance currents are propagated in the upstream electrical network. Also, the created harmonics put the power quality of the traction system in danger. In this paper the traction system load is characterized, an algorithm for compensating simultaneously the both harmonics and load unbalances, and a topology of Hybrid Active Power Filter (HAFP) for improving of power quality in upstream network and the traction system is presented. The proposed algorithm can be adapted to any traction transformer connections / configurations. Besides, the load side compensation is used which reduces the cost of installations. And the proposed topology caused reducing the size of the Active Power Filter (APF). The topology is successfully tested under normal operation and load change conditions. The simulation results show the good performance of the algorithm under non-stiff supply network as well.\",\"PeriodicalId\":166144,\"journal\":{\"name\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2011.6036545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

电气化牵引系统的供电系统存在电能质量问题。这主要是由于牵引系统驱动的电力电子变换器及其单相运行所致。产生的谐波和不平衡电流在上游电网中传播。此外,产生的谐波使牵引系统的电能质量处于危险之中。本文分析了牵引系统的负载特征,提出了谐波和负载不平衡同步补偿算法,并提出了一种用于改善上游电网和牵引系统电能质量的混合有源滤波器(HAFP)拓扑结构。该算法可适用于任何牵引变压器连接/配置。此外,还采用了负荷侧补偿,降低了安装成本。提出的拓扑结构减小了有源电力滤波器(APF)的尺寸。该拓扑在正常运行和负载变化条件下成功测试。仿真结果表明,该算法在非刚性供电网络下也具有良好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A topology of Hybrid Active Power Filter for simultaneously compensating harmonics and load unbalance in single phase traction systems
Electrified Traction systems cause power quality problems in their power supply system. This is mainly due to the power electronic converters of traction system drives and their single phase operation. The created harmonics and unbalance currents are propagated in the upstream electrical network. Also, the created harmonics put the power quality of the traction system in danger. In this paper the traction system load is characterized, an algorithm for compensating simultaneously the both harmonics and load unbalances, and a topology of Hybrid Active Power Filter (HAFP) for improving of power quality in upstream network and the traction system is presented. The proposed algorithm can be adapted to any traction transformer connections / configurations. Besides, the load side compensation is used which reduces the cost of installations. And the proposed topology caused reducing the size of the Active Power Filter (APF). The topology is successfully tested under normal operation and load change conditions. The simulation results show the good performance of the algorithm under non-stiff supply network as well.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low cost DC lines PLC based photovoltaic plants parameters smart monitoring communications and control module Smart meters for distributed filtering of high harmonics in Smart Grid FPGA controller for power converters with integrated oscilloscope and graphical user interface On the square arc voltage waveform model in magnetic discharge lamp studies Interplay of Smart Grids and Intelligent Systems and Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1