{"title":"TELBECC -用于分析电话建筑能耗和控制的计算方法和计算机程序","authors":"P. B. Grimado","doi":"10.1002/J.1538-7305.1983.TB03461.X","DOIUrl":null,"url":null,"abstract":"Telephone Building Energy Consumption and Control (TELBECC) program has been developed to accurately and efficiently analyze environmental control and energy use in telephone company buildings. The program simulates various operational plans to determine the relative energy and cost savings. By analyzing the operation of the heating, ventilation, and air conditioning system as it regulates a changing environment, TELBECC calculates the heating and cooling load, dry-bulb temperature, and relative humidity in the building. The user specifies the building's dry-bulb temperature limits, which are the control variables for the program analysis. The simplified computational procedure of the program incorporates a recursive scheme using time series to perform the necessary calculations. The results of the computations can be obtained for different periods: the quarter hour, hour, day, or month. Energy consumption and control in several equipment buildings located in three different geographical areas have been analyzed by TELBECC. Analysis and comparison of the resulting data demonstrate the advantages of the program.","PeriodicalId":447574,"journal":{"name":"The Bell System Technical Journal","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1983-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"TELBECC — A computational method and computer program for analyzing Telephone Building Energy Consumption and Control\",\"authors\":\"P. B. Grimado\",\"doi\":\"10.1002/J.1538-7305.1983.TB03461.X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Telephone Building Energy Consumption and Control (TELBECC) program has been developed to accurately and efficiently analyze environmental control and energy use in telephone company buildings. The program simulates various operational plans to determine the relative energy and cost savings. By analyzing the operation of the heating, ventilation, and air conditioning system as it regulates a changing environment, TELBECC calculates the heating and cooling load, dry-bulb temperature, and relative humidity in the building. The user specifies the building's dry-bulb temperature limits, which are the control variables for the program analysis. The simplified computational procedure of the program incorporates a recursive scheme using time series to perform the necessary calculations. The results of the computations can be obtained for different periods: the quarter hour, hour, day, or month. Energy consumption and control in several equipment buildings located in three different geographical areas have been analyzed by TELBECC. Analysis and comparison of the resulting data demonstrate the advantages of the program.\",\"PeriodicalId\":447574,\"journal\":{\"name\":\"The Bell System Technical Journal\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Bell System Technical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/J.1538-7305.1983.TB03461.X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Bell System Technical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/J.1538-7305.1983.TB03461.X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
TELBECC — A computational method and computer program for analyzing Telephone Building Energy Consumption and Control
Telephone Building Energy Consumption and Control (TELBECC) program has been developed to accurately and efficiently analyze environmental control and energy use in telephone company buildings. The program simulates various operational plans to determine the relative energy and cost savings. By analyzing the operation of the heating, ventilation, and air conditioning system as it regulates a changing environment, TELBECC calculates the heating and cooling load, dry-bulb temperature, and relative humidity in the building. The user specifies the building's dry-bulb temperature limits, which are the control variables for the program analysis. The simplified computational procedure of the program incorporates a recursive scheme using time series to perform the necessary calculations. The results of the computations can be obtained for different periods: the quarter hour, hour, day, or month. Energy consumption and control in several equipment buildings located in three different geographical areas have been analyzed by TELBECC. Analysis and comparison of the resulting data demonstrate the advantages of the program.