乌克兰南极维尔纳德斯基科考站地磁观测站磁力计柱间地磁感应差的测量

M. Leonov, Y. Otruba
{"title":"乌克兰南极维尔纳德斯基科考站地磁观测站磁力计柱间地磁感应差的测量","authors":"M. Leonov, Y. Otruba","doi":"10.33275/1727-7485.1.2021.662","DOIUrl":null,"url":null,"abstract":"The article describes the features of measurements of spatial inhomogeneities of the geomagnetic field between the pillars of magnetometers in the measuring pavilion, which were carried out at the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station in 2015. Some preliminary results of these measurements are also given. The concept of the timescaled value of the geomagnetic field induction is introduced, which is convenient for compensating for time changes of the real geomagnetic induction and bringing it to one reference level of induction. The differences in geomagnetic induction between pillars are obtained as the differences in time-scaled values of the geomagnetic induction on the pillars. The technique allows comparing long-term series of measurements of field inhomogeneities at important points in space. The main objectives are to increase the accuracy of measurements of local inhomogeneities of the geomagnetic field in the measuring pavilion of the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station and to determine the differences in the geomagnetic induction between the pillars on which the magnetometer sensors are installed. Obtaining numerical values of the differences in the geomagnetic induction between the pillars as objective criteria needed to assess the accuracy of the data in the final processing of geomagnetic observatory data. The method of comparison of two series of data is used: one obtained by the scalar magnetometer installed in the observatory as a mandatory stationary device, and the other obtained during measurements with a mobile magnetometer at the desired points in space. Compensation of temporal changes of the geomagnetic field by time-scaling the measurement readings of the mobile magnetometer relative to one reference value and thus, bringing them to one selected and fixed time epoch. Special geometric scheme of mobile measurements in the space around the pillars with magnetometer sensors or at important points in space. A rough estimate of method errors. Based on the analysis of the obtained data, the efficiency of the method and its acceptable potential accuracy were confirmed. We obtained approximate numerical values of the differences in the geomagnetic field induction between the pillars on which the magnetometer sensors are installed. Further increase in the accuracy of determining these differences is possible using modern devices of high accuracy and GPS-synchronization of mobile measurements.","PeriodicalId":370867,"journal":{"name":"Ukrainian Antarctic Journal","volume":"163 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of the difference in the geomagnetic induction between the magnetometer pillars of the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station\",\"authors\":\"M. Leonov, Y. Otruba\",\"doi\":\"10.33275/1727-7485.1.2021.662\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article describes the features of measurements of spatial inhomogeneities of the geomagnetic field between the pillars of magnetometers in the measuring pavilion, which were carried out at the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station in 2015. Some preliminary results of these measurements are also given. The concept of the timescaled value of the geomagnetic field induction is introduced, which is convenient for compensating for time changes of the real geomagnetic induction and bringing it to one reference level of induction. The differences in geomagnetic induction between pillars are obtained as the differences in time-scaled values of the geomagnetic induction on the pillars. The technique allows comparing long-term series of measurements of field inhomogeneities at important points in space. The main objectives are to increase the accuracy of measurements of local inhomogeneities of the geomagnetic field in the measuring pavilion of the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station and to determine the differences in the geomagnetic induction between the pillars on which the magnetometer sensors are installed. Obtaining numerical values of the differences in the geomagnetic induction between the pillars as objective criteria needed to assess the accuracy of the data in the final processing of geomagnetic observatory data. The method of comparison of two series of data is used: one obtained by the scalar magnetometer installed in the observatory as a mandatory stationary device, and the other obtained during measurements with a mobile magnetometer at the desired points in space. Compensation of temporal changes of the geomagnetic field by time-scaling the measurement readings of the mobile magnetometer relative to one reference value and thus, bringing them to one selected and fixed time epoch. Special geometric scheme of mobile measurements in the space around the pillars with magnetometer sensors or at important points in space. A rough estimate of method errors. Based on the analysis of the obtained data, the efficiency of the method and its acceptable potential accuracy were confirmed. We obtained approximate numerical values of the differences in the geomagnetic field induction between the pillars on which the magnetometer sensors are installed. Further increase in the accuracy of determining these differences is possible using modern devices of high accuracy and GPS-synchronization of mobile measurements.\",\"PeriodicalId\":370867,\"journal\":{\"name\":\"Ukrainian Antarctic Journal\",\"volume\":\"163 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ukrainian Antarctic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33275/1727-7485.1.2021.662\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ukrainian Antarctic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33275/1727-7485.1.2021.662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了2015年在乌克兰南极科学院维尔纳德斯基站地磁观测站进行的测量馆磁力计柱间地磁场空间非均质性测量的特点。并给出了这些测量的一些初步结果。引入地磁感应强度时标值的概念,便于对实际地磁感应强度的时间变化进行补偿,使其达到一个参考水平。地磁感应强度的差异是地磁感应强度在时间尺度上的差异。这项技术可以比较空间中重要地点的场不均匀性的长期系列测量结果。主要目标是提高乌克兰南极维尔纳德斯基科学院站地磁观测站测量亭对局部地磁场不均匀性测量的准确性,并确定安装磁力计传感器的柱子之间地磁感应的差异。在地磁观测数据的最终处理中,获得地磁柱间地磁感应差的数值作为评价数据精度的客观标准。采用了两组数据比较的方法:一组数据是由天文台固定装置的标量磁力计获得的,另一组数据是由移动磁力计在空间所需点测量时获得的。将移动磁力计的测量读数相对于一个参考值进行时间标度,从而使它们达到一个选定的固定时间历元,从而补偿地磁场的时间变化。用磁力计传感器在柱子周围的空间或空间的重要位置进行移动测量的特殊几何方案。对方法误差的粗略估计。通过对实测数据的分析,验证了该方法的有效性和可接受的潜在精度。我们得到了安装磁力计传感器的柱间地磁场感应差的近似数值。使用高精度的现代设备和gps同步移动测量,可以进一步提高确定这些差异的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement of the difference in the geomagnetic induction between the magnetometer pillars of the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station
The article describes the features of measurements of spatial inhomogeneities of the geomagnetic field between the pillars of magnetometers in the measuring pavilion, which were carried out at the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station in 2015. Some preliminary results of these measurements are also given. The concept of the timescaled value of the geomagnetic field induction is introduced, which is convenient for compensating for time changes of the real geomagnetic induction and bringing it to one reference level of induction. The differences in geomagnetic induction between pillars are obtained as the differences in time-scaled values of the geomagnetic induction on the pillars. The technique allows comparing long-term series of measurements of field inhomogeneities at important points in space. The main objectives are to increase the accuracy of measurements of local inhomogeneities of the geomagnetic field in the measuring pavilion of the geomagnetic observatory of the Ukrainian Antarctic Akademik Vernadsky station and to determine the differences in the geomagnetic induction between the pillars on which the magnetometer sensors are installed. Obtaining numerical values of the differences in the geomagnetic induction between the pillars as objective criteria needed to assess the accuracy of the data in the final processing of geomagnetic observatory data. The method of comparison of two series of data is used: one obtained by the scalar magnetometer installed in the observatory as a mandatory stationary device, and the other obtained during measurements with a mobile magnetometer at the desired points in space. Compensation of temporal changes of the geomagnetic field by time-scaling the measurement readings of the mobile magnetometer relative to one reference value and thus, bringing them to one selected and fixed time epoch. Special geometric scheme of mobile measurements in the space around the pillars with magnetometer sensors or at important points in space. A rough estimate of method errors. Based on the analysis of the obtained data, the efficiency of the method and its acceptable potential accuracy were confirmed. We obtained approximate numerical values of the differences in the geomagnetic field induction between the pillars on which the magnetometer sensors are installed. Further increase in the accuracy of determining these differences is possible using modern devices of high accuracy and GPS-synchronization of mobile measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Benthic wildlife underwater video recording during longline survey in Weddell Sea Modelling seasonal and intraseasonal variations of circulation,temperature, salinity and sea level in the Bellingshausen Seaand on the Antarctic Peninsula shelf Microclimatic variations of land surface temperatureon Galindez Island (western part of the Antarctic Peninsula) Assessment of the zonal asymmetry trend in Antarctic total ozonecolumn using TOMS measurements and CCMVal-2 models Long-term analysis of the Antarctic total ozone zonal asymmetry by MERRA-2 and CMIP6 data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1