{"title":"利用节能技术降低高密度环境下的运行成本","authors":"P. Gross, K. L. Godrich","doi":"10.1109/INTLEC.2006.251651","DOIUrl":null,"url":null,"abstract":"High-density server facilities have quickly become a widespread reality. Not only are they adding nearly 1 GW to the US economy load, but many of these major data centers are using this increase in power in a way that exceeds all market expectations. Past predictions for high-density servers racks in the year 2006 showed loads in the neighborhood of 8 KW, but today's reality shows it is in the magnitude of 300% higher-and in some case even more, racks of 35 KW are installed and commissioned. Why are we so far ahead of the forecast for needed energy? Power-hungry processors and super-charged servers","PeriodicalId":356699,"journal":{"name":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","volume":"2016 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Using Energy-Efficient Technologies to Lower Operational Costs in High-Density Environment\",\"authors\":\"P. Gross, K. L. Godrich\",\"doi\":\"10.1109/INTLEC.2006.251651\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High-density server facilities have quickly become a widespread reality. Not only are they adding nearly 1 GW to the US economy load, but many of these major data centers are using this increase in power in a way that exceeds all market expectations. Past predictions for high-density servers racks in the year 2006 showed loads in the neighborhood of 8 KW, but today's reality shows it is in the magnitude of 300% higher-and in some case even more, racks of 35 KW are installed and commissioned. Why are we so far ahead of the forecast for needed energy? Power-hungry processors and super-charged servers\",\"PeriodicalId\":356699,\"journal\":{\"name\":\"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference\",\"volume\":\"2016 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INTLEC.2006.251651\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"INTELEC 06 - Twenty-Eighth International Telecommunications Energy Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INTLEC.2006.251651","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Using Energy-Efficient Technologies to Lower Operational Costs in High-Density Environment
High-density server facilities have quickly become a widespread reality. Not only are they adding nearly 1 GW to the US economy load, but many of these major data centers are using this increase in power in a way that exceeds all market expectations. Past predictions for high-density servers racks in the year 2006 showed loads in the neighborhood of 8 KW, but today's reality shows it is in the magnitude of 300% higher-and in some case even more, racks of 35 KW are installed and commissioned. Why are we so far ahead of the forecast for needed energy? Power-hungry processors and super-charged servers