L. Nicu, T. Alava, F. Mathieu, C. Ayela, C. Soyer, D. Remiens
{"title":"微尺度下的驱动和传感集成挑战:共振生物机械领域的死结","authors":"L. Nicu, T. Alava, F. Mathieu, C. Ayela, C. Soyer, D. Remiens","doi":"10.1109/FREQ.2010.5556369","DOIUrl":null,"url":null,"abstract":"Sensing platforms (5mm*5mm) containing 5 piezoelectric membranes have been fabricated by standard micromachining techniques starting with a Silicon-On-Insulator wafer. Each membrane (circular, with radius varying from 360 microns to 440 microns) could be individually actuated through a PZT 1-micron thick film and sensed either via the same piezoelectric patch or via two terminal piezoresistances (obtained by boron implantation) placed at high-stress location onto the devices. Specific associated electronics (bandwidth of 2 MHz) have been designed and realized so that multiplexed actuation and sensing of all membranes resonant frequencies can be performed either in open-loop or closed-loop mode.","PeriodicalId":344989,"journal":{"name":"2010 IEEE International Frequency Control Symposium","volume":"283 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Actuation and sensing integration challenges at the microscale: the Gordian Knot of the resonant bioMEMS realm\",\"authors\":\"L. Nicu, T. Alava, F. Mathieu, C. Ayela, C. Soyer, D. Remiens\",\"doi\":\"10.1109/FREQ.2010.5556369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sensing platforms (5mm*5mm) containing 5 piezoelectric membranes have been fabricated by standard micromachining techniques starting with a Silicon-On-Insulator wafer. Each membrane (circular, with radius varying from 360 microns to 440 microns) could be individually actuated through a PZT 1-micron thick film and sensed either via the same piezoelectric patch or via two terminal piezoresistances (obtained by boron implantation) placed at high-stress location onto the devices. Specific associated electronics (bandwidth of 2 MHz) have been designed and realized so that multiplexed actuation and sensing of all membranes resonant frequencies can be performed either in open-loop or closed-loop mode.\",\"PeriodicalId\":344989,\"journal\":{\"name\":\"2010 IEEE International Frequency Control Symposium\",\"volume\":\"283 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE International Frequency Control Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FREQ.2010.5556369\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Frequency Control Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.2010.5556369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Actuation and sensing integration challenges at the microscale: the Gordian Knot of the resonant bioMEMS realm
Sensing platforms (5mm*5mm) containing 5 piezoelectric membranes have been fabricated by standard micromachining techniques starting with a Silicon-On-Insulator wafer. Each membrane (circular, with radius varying from 360 microns to 440 microns) could be individually actuated through a PZT 1-micron thick film and sensed either via the same piezoelectric patch or via two terminal piezoresistances (obtained by boron implantation) placed at high-stress location onto the devices. Specific associated electronics (bandwidth of 2 MHz) have been designed and realized so that multiplexed actuation and sensing of all membranes resonant frequencies can be performed either in open-loop or closed-loop mode.