Zhao Zhihong, Zhao Yue, Cheng Lei, Wang Bin, Huang Zhihua
{"title":"短线距离保护I区保护范围的研究","authors":"Zhao Zhihong, Zhao Yue, Cheng Lei, Wang Bin, Huang Zhihua","doi":"10.1109/ciced.2018.8592250","DOIUrl":null,"url":null,"abstract":"This thesis mainly analyzes the applications of distance protection zone I for short transmission line or weak-infeed. It demonstrates the calculation method of shortest length of transmission line that distance protection zone I can be applied at power source side and gives suggestions of setting calculation. Moreover, it analyzes the large error between measured impedance value and actual fault impedance, because distance protection zone I may work improperly when distance protection used for weak-infeed side.","PeriodicalId":142885,"journal":{"name":"2018 China International Conference on Electricity Distribution (CICED)","volume":"147 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on the Protection Range of Distance Protection Zone I for Short Transmission Line\",\"authors\":\"Zhao Zhihong, Zhao Yue, Cheng Lei, Wang Bin, Huang Zhihua\",\"doi\":\"10.1109/ciced.2018.8592250\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This thesis mainly analyzes the applications of distance protection zone I for short transmission line or weak-infeed. It demonstrates the calculation method of shortest length of transmission line that distance protection zone I can be applied at power source side and gives suggestions of setting calculation. Moreover, it analyzes the large error between measured impedance value and actual fault impedance, because distance protection zone I may work improperly when distance protection used for weak-infeed side.\",\"PeriodicalId\":142885,\"journal\":{\"name\":\"2018 China International Conference on Electricity Distribution (CICED)\",\"volume\":\"147 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 China International Conference on Electricity Distribution (CICED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ciced.2018.8592250\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ciced.2018.8592250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on the Protection Range of Distance Protection Zone I for Short Transmission Line
This thesis mainly analyzes the applications of distance protection zone I for short transmission line or weak-infeed. It demonstrates the calculation method of shortest length of transmission line that distance protection zone I can be applied at power source side and gives suggestions of setting calculation. Moreover, it analyzes the large error between measured impedance value and actual fault impedance, because distance protection zone I may work improperly when distance protection used for weak-infeed side.