{"title":"基于灰色关联分析技术的多普勒超声信号去噪","authors":"E. Uzunhisarcikli, F. Latifoğlu, T. Koza, M. Kaya","doi":"10.1109/BIYOMUT.2009.5130309","DOIUrl":null,"url":null,"abstract":"In this study, Grey relational analysis technique proposed by J.L. Deng has been applied to spectrogram images of clinical mitral valve Doppler signals. A threshold level has been determined to plot maximum frequency envelope from denoised sonogram image using this technique. It is seen that, signal to noise ratio has been improved through Grey relational analysis technique. A software has been realized to support Doppler ultrasound device to diagnose vascular disease. This system has many advanteges that are reducing the computation time, ergonomic, cheapness.","PeriodicalId":119026,"journal":{"name":"2009 14th National Biomedical Engineering Meeting","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Doppler ultrasound signal denoising based on Grey relational analysis technique\",\"authors\":\"E. Uzunhisarcikli, F. Latifoğlu, T. Koza, M. Kaya\",\"doi\":\"10.1109/BIYOMUT.2009.5130309\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, Grey relational analysis technique proposed by J.L. Deng has been applied to spectrogram images of clinical mitral valve Doppler signals. A threshold level has been determined to plot maximum frequency envelope from denoised sonogram image using this technique. It is seen that, signal to noise ratio has been improved through Grey relational analysis technique. A software has been realized to support Doppler ultrasound device to diagnose vascular disease. This system has many advanteges that are reducing the computation time, ergonomic, cheapness.\",\"PeriodicalId\":119026,\"journal\":{\"name\":\"2009 14th National Biomedical Engineering Meeting\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 14th National Biomedical Engineering Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIYOMUT.2009.5130309\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 14th National Biomedical Engineering Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIYOMUT.2009.5130309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Doppler ultrasound signal denoising based on Grey relational analysis technique
In this study, Grey relational analysis technique proposed by J.L. Deng has been applied to spectrogram images of clinical mitral valve Doppler signals. A threshold level has been determined to plot maximum frequency envelope from denoised sonogram image using this technique. It is seen that, signal to noise ratio has been improved through Grey relational analysis technique. A software has been realized to support Doppler ultrasound device to diagnose vascular disease. This system has many advanteges that are reducing the computation time, ergonomic, cheapness.