三维多芯片模块和微型散热器的液体冷却性能

M. Vogel
{"title":"三维多芯片模块和微型散热器的液体冷却性能","authors":"M. Vogel","doi":"10.1109/STHERM.1994.288991","DOIUrl":null,"url":null,"abstract":"Measured thermal performance is presented for a single phase liquid-cooled module. Tape automated bonded (TAB) thermal test chips and their associated substrates are stacked in a compact, 3-dimensional liquid tight module. A dielectric liquid, polyalphaolefin (PAO) is forced to flow past the active and inactive sides of the TAB chips. At a volumetric flowrate of 0.05 gallons per minute (gpm) and an estimated pressure loss less than 0.5 psi. the measured junction-to-liquid thermal resistance is 2.0 C/W for a 0.50\"/spl times/0.50\"/spl times/0.015\" thermal test chip. The thermal resistance was also measured for an indirect liquid cooling approach. PAO was used to cool a miniature sink mounted directly to a 0.50\"/spl times/0.50\" heat source. The heat source was used to simulate the thermal characteristics of a chip carrier package. Overall dimensions of the liquid heat sink measured 1.0\"/spl times/1.0\"/spl times/0.28\". The measured junction-to-liquid thermal resistance is 0.52 C/W for a flowrate of 0.05 gpm. and for an estimated pressure loss less than 1.0 psi. Numerical computational techniques yielded results which were comparable to the measured thermal resistances for both the 3-dimensional module and the miniature heat sink. Enhanced thermal performance gained by introducing micro encapsulated phase change material to the PAO is estimated for both the 3-dimensional module and the miniature heat sink.<<ETX>>","PeriodicalId":107140,"journal":{"name":"Proceedings of 1994 IEEE/CHMT 10th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1994-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Liquid cooling performance for a 3-dimensional multichip module and miniature heat sink\",\"authors\":\"M. Vogel\",\"doi\":\"10.1109/STHERM.1994.288991\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measured thermal performance is presented for a single phase liquid-cooled module. Tape automated bonded (TAB) thermal test chips and their associated substrates are stacked in a compact, 3-dimensional liquid tight module. A dielectric liquid, polyalphaolefin (PAO) is forced to flow past the active and inactive sides of the TAB chips. At a volumetric flowrate of 0.05 gallons per minute (gpm) and an estimated pressure loss less than 0.5 psi. the measured junction-to-liquid thermal resistance is 2.0 C/W for a 0.50\\\"/spl times/0.50\\\"/spl times/0.015\\\" thermal test chip. The thermal resistance was also measured for an indirect liquid cooling approach. PAO was used to cool a miniature sink mounted directly to a 0.50\\\"/spl times/0.50\\\" heat source. The heat source was used to simulate the thermal characteristics of a chip carrier package. Overall dimensions of the liquid heat sink measured 1.0\\\"/spl times/1.0\\\"/spl times/0.28\\\". The measured junction-to-liquid thermal resistance is 0.52 C/W for a flowrate of 0.05 gpm. and for an estimated pressure loss less than 1.0 psi. Numerical computational techniques yielded results which were comparable to the measured thermal resistances for both the 3-dimensional module and the miniature heat sink. Enhanced thermal performance gained by introducing micro encapsulated phase change material to the PAO is estimated for both the 3-dimensional module and the miniature heat sink.<<ETX>>\",\"PeriodicalId\":107140,\"journal\":{\"name\":\"Proceedings of 1994 IEEE/CHMT 10th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1994 IEEE/CHMT 10th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STHERM.1994.288991\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 IEEE/CHMT 10th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STHERM.1994.288991","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

介绍了一种单相液冷模块的热性能测量方法。胶带自动粘合(TAB)热测试芯片及其相关基板堆叠在紧凑的三维液密模块中。一种介电液体,聚α -烯烃(PAO)被强迫流过TAB芯片的活性和非活性两侧。体积流量为0.05加仑/分钟(gpm),估计压力损失小于0.5 psi。对于0.50"/spl倍/0.50"/spl倍/0.015"热测试芯片,测量到的结液热阻为2.0 C/W。还测量了间接液体冷却方法的热阻。PAO用于冷却直接安装在0.50“/spl倍/0.50”热源上的微型水槽。利用该热源模拟了芯片载体封装的热特性。液体散热器的整体尺寸测量为1.0"/spl倍/1.0"/spl倍/0.28"。测量的结液热阻为0.52 C/W,流速为0.05 gpm。并且估计压力损失小于1.0 psi。数值计算技术产生的结果与三维模块和微型散热器的测量热阻相当。通过在PAO中引入微封装相变材料,估计三维模块和微型散热器的热性能都得到了提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Liquid cooling performance for a 3-dimensional multichip module and miniature heat sink
Measured thermal performance is presented for a single phase liquid-cooled module. Tape automated bonded (TAB) thermal test chips and their associated substrates are stacked in a compact, 3-dimensional liquid tight module. A dielectric liquid, polyalphaolefin (PAO) is forced to flow past the active and inactive sides of the TAB chips. At a volumetric flowrate of 0.05 gallons per minute (gpm) and an estimated pressure loss less than 0.5 psi. the measured junction-to-liquid thermal resistance is 2.0 C/W for a 0.50"/spl times/0.50"/spl times/0.015" thermal test chip. The thermal resistance was also measured for an indirect liquid cooling approach. PAO was used to cool a miniature sink mounted directly to a 0.50"/spl times/0.50" heat source. The heat source was used to simulate the thermal characteristics of a chip carrier package. Overall dimensions of the liquid heat sink measured 1.0"/spl times/1.0"/spl times/0.28". The measured junction-to-liquid thermal resistance is 0.52 C/W for a flowrate of 0.05 gpm. and for an estimated pressure loss less than 1.0 psi. Numerical computational techniques yielded results which were comparable to the measured thermal resistances for both the 3-dimensional module and the miniature heat sink. Enhanced thermal performance gained by introducing micro encapsulated phase change material to the PAO is estimated for both the 3-dimensional module and the miniature heat sink.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An exact solution of the steady-state surface temperature for a general multilayer structure Advanced micro air-cooling systems for high density packaging GaAs MMIC thermal modeling for channel temperatures in accelerated life test fixtures and microwave modules Effect of circuit board parameters on thermal performance of electronic components in natural convection cooling Thermal performance of air-cooled hybrid heat sinks for a low velocity environment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1