Robert Rogersten, L. Vanfretti, Wei Li, Lidong Zhang, P. Mitra
{"title":"EMT工具中VSC-HVdc控制器仿真的定量评估方法","authors":"Robert Rogersten, L. Vanfretti, Wei Li, Lidong Zhang, P. Mitra","doi":"10.1109/ISGTEUROPE.2014.7028824","DOIUrl":null,"url":null,"abstract":"Voltage-Source Converter-Based High-voltage dc (VSC-HVdc) technology has received growing interest during recent years due to its benefits for separated active and reactive power control. Before the installation of VSC-HVdc links, different simulation-based studies need to be performed, usually by different parties and using different electromagnetic transient (EMT) simulation platforms. This paper provides a systematic method to assess discrepancies between simulation tools. Models of the VSC and its control systems are implemented from scratch in two different tools. A metric and a methodology to quantitatively assess the discrepancies between simulation results is proposed and illustrated. The paper shows that even with a pedantic re-implementation of the models from the ground up, simulation results are still inconsistent. The objective of this paper is to develop a quantification method for comparing the models developed in different EMT simulation tool and to emphasize differences that can arise with the numerical solvers in such tools.","PeriodicalId":299515,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies, Europe","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A quantitative method for the assessment of VSC-HVdc controller simulations in EMT tools\",\"authors\":\"Robert Rogersten, L. Vanfretti, Wei Li, Lidong Zhang, P. Mitra\",\"doi\":\"10.1109/ISGTEUROPE.2014.7028824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage-Source Converter-Based High-voltage dc (VSC-HVdc) technology has received growing interest during recent years due to its benefits for separated active and reactive power control. Before the installation of VSC-HVdc links, different simulation-based studies need to be performed, usually by different parties and using different electromagnetic transient (EMT) simulation platforms. This paper provides a systematic method to assess discrepancies between simulation tools. Models of the VSC and its control systems are implemented from scratch in two different tools. A metric and a methodology to quantitatively assess the discrepancies between simulation results is proposed and illustrated. The paper shows that even with a pedantic re-implementation of the models from the ground up, simulation results are still inconsistent. The objective of this paper is to develop a quantification method for comparing the models developed in different EMT simulation tool and to emphasize differences that can arise with the numerical solvers in such tools.\",\"PeriodicalId\":299515,\"journal\":{\"name\":\"IEEE PES Innovative Smart Grid Technologies, Europe\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PES Innovative Smart Grid Technologies, Europe\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEUROPE.2014.7028824\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies, Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEUROPE.2014.7028824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A quantitative method for the assessment of VSC-HVdc controller simulations in EMT tools
Voltage-Source Converter-Based High-voltage dc (VSC-HVdc) technology has received growing interest during recent years due to its benefits for separated active and reactive power control. Before the installation of VSC-HVdc links, different simulation-based studies need to be performed, usually by different parties and using different electromagnetic transient (EMT) simulation platforms. This paper provides a systematic method to assess discrepancies between simulation tools. Models of the VSC and its control systems are implemented from scratch in two different tools. A metric and a methodology to quantitatively assess the discrepancies between simulation results is proposed and illustrated. The paper shows that even with a pedantic re-implementation of the models from the ground up, simulation results are still inconsistent. The objective of this paper is to develop a quantification method for comparing the models developed in different EMT simulation tool and to emphasize differences that can arise with the numerical solvers in such tools.