{"title":"优化RC定时技术,精确测量微小的电容变化","authors":"Z. Zaharudin, I. Adam, K. Kadir, Sheroz Khan, A. Nurashikin, Faraz Ahmad Shaikh, A. Abdalla, N. Malik, W. Morshidi","doi":"10.1109/ICETSS.2017.8324196","DOIUrl":null,"url":null,"abstract":"This paper presents a technique for accurate measurement of small capacitive changes. This is based on selecting the most linear part of the curve obtained by charging the capacitor undergoing changes through a known resistor value. This measurement is part of the design of a system for measuring blood glucose content non-invasively. The technique is based on measuring ultra-low low glucose levels in the blood as capacitive changes converted into RC timing constant optimized using a circuit set to trigger at an appropriate time activating a counter. The measured data is captured instant later, selecting the most linear part of the charging curve. The results so obtained are compared with the ones obtained through RC-timing standard procedure. The technique reported is with a remarkable low error of about 2.25% as against 11.78% by the standard RC-timing technique.","PeriodicalId":228333,"journal":{"name":"2017 IEEE 3rd International Conference on Engineering Technologies and Social Sciences (ICETSS)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimized RC timing technique for accurate measurement of minute capacitance changes\",\"authors\":\"Z. Zaharudin, I. Adam, K. Kadir, Sheroz Khan, A. Nurashikin, Faraz Ahmad Shaikh, A. Abdalla, N. Malik, W. Morshidi\",\"doi\":\"10.1109/ICETSS.2017.8324196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a technique for accurate measurement of small capacitive changes. This is based on selecting the most linear part of the curve obtained by charging the capacitor undergoing changes through a known resistor value. This measurement is part of the design of a system for measuring blood glucose content non-invasively. The technique is based on measuring ultra-low low glucose levels in the blood as capacitive changes converted into RC timing constant optimized using a circuit set to trigger at an appropriate time activating a counter. The measured data is captured instant later, selecting the most linear part of the charging curve. The results so obtained are compared with the ones obtained through RC-timing standard procedure. The technique reported is with a remarkable low error of about 2.25% as against 11.78% by the standard RC-timing technique.\",\"PeriodicalId\":228333,\"journal\":{\"name\":\"2017 IEEE 3rd International Conference on Engineering Technologies and Social Sciences (ICETSS)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 3rd International Conference on Engineering Technologies and Social Sciences (ICETSS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICETSS.2017.8324196\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 3rd International Conference on Engineering Technologies and Social Sciences (ICETSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETSS.2017.8324196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimized RC timing technique for accurate measurement of minute capacitance changes
This paper presents a technique for accurate measurement of small capacitive changes. This is based on selecting the most linear part of the curve obtained by charging the capacitor undergoing changes through a known resistor value. This measurement is part of the design of a system for measuring blood glucose content non-invasively. The technique is based on measuring ultra-low low glucose levels in the blood as capacitive changes converted into RC timing constant optimized using a circuit set to trigger at an appropriate time activating a counter. The measured data is captured instant later, selecting the most linear part of the charging curve. The results so obtained are compared with the ones obtained through RC-timing standard procedure. The technique reported is with a remarkable low error of about 2.25% as against 11.78% by the standard RC-timing technique.