Yuki Ikemoto, Y. Imamura, Yuki Takagi, H. Kudo
{"title":"使用滤纸收集唾液的简化唾液尿酸传感系统","authors":"Yuki Ikemoto, Y. Imamura, Yuki Takagi, H. Kudo","doi":"10.1109/BMEICON.2018.8609993","DOIUrl":null,"url":null,"abstract":"Here, we report an electrochemical biosensor aimed at daily self-check of salivary uric acid (UA). For this purpose, a paper-based sampling device and an amperometric biosensor with a reaction chamber designed for inserting the sampling device were employed. Our sampling device was made of a flexible material based on filter paper and it is possible to collect certain amount of saliva with sufficient reproducibility by gently putting it on the salivary gland for about 5 seconds. The biosensor measures UA contained in the sampling device by inserting it into the reaction chamber, filled with phosphate buffer saline (PBS). The output current of the biosensor was proportional to the concentration of UA, which contained in the solution collected by the sampling device, from 10 μM – 400 μM. As a real sample test, the biosensor was used for the measurement of UA levels of a healthy male volunteer. The output current increased immediately when the sampling device containing saliva was inserted to the reaction chamber. Concentration of salivary UA was estimated to 150 μM, which value was compatible to the reported UA levels in saliva.","PeriodicalId":232271,"journal":{"name":"2018 11th Biomedical Engineering International Conference (BMEiCON)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simplified Salivary Uric acid Sensing System using a Filter paper for Saliva Collection\",\"authors\":\"Yuki Ikemoto, Y. Imamura, Yuki Takagi, H. Kudo\",\"doi\":\"10.1109/BMEICON.2018.8609993\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Here, we report an electrochemical biosensor aimed at daily self-check of salivary uric acid (UA). For this purpose, a paper-based sampling device and an amperometric biosensor with a reaction chamber designed for inserting the sampling device were employed. Our sampling device was made of a flexible material based on filter paper and it is possible to collect certain amount of saliva with sufficient reproducibility by gently putting it on the salivary gland for about 5 seconds. The biosensor measures UA contained in the sampling device by inserting it into the reaction chamber, filled with phosphate buffer saline (PBS). The output current of the biosensor was proportional to the concentration of UA, which contained in the solution collected by the sampling device, from 10 μM – 400 μM. As a real sample test, the biosensor was used for the measurement of UA levels of a healthy male volunteer. The output current increased immediately when the sampling device containing saliva was inserted to the reaction chamber. Concentration of salivary UA was estimated to 150 μM, which value was compatible to the reported UA levels in saliva.\",\"PeriodicalId\":232271,\"journal\":{\"name\":\"2018 11th Biomedical Engineering International Conference (BMEiCON)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 11th Biomedical Engineering International Conference (BMEiCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEICON.2018.8609993\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 11th Biomedical Engineering International Conference (BMEiCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEICON.2018.8609993","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这里,我们报告了一种电化学生物传感器,旨在每日自检唾液尿酸(UA)。为此,采用了基于纸张的采样装置和带有用于插入采样装置的反应室的安培生物传感器。我们的采样装置是由一种基于滤纸的柔性材料制成的,轻轻放在唾液腺上5秒左右,就可以收集一定量的唾液,并有足够的再现性。生物传感器通过将采样装置插入充满磷酸盐缓冲盐水(PBS)的反应室来测量采样装置中所含的UA。生物传感器的输出电流在10 μM ~ 400 μM范围内与采样装置采集的溶液中UA的浓度成正比。作为一个真实的样本测试,生物传感器被用于测量健康男性志愿者的UA水平。当将含有唾液的取样装置插入反应室时,输出电流立即增加。唾液UA的浓度估计为150 μM,该值与报道的唾液UA水平一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simplified Salivary Uric acid Sensing System using a Filter paper for Saliva Collection
Here, we report an electrochemical biosensor aimed at daily self-check of salivary uric acid (UA). For this purpose, a paper-based sampling device and an amperometric biosensor with a reaction chamber designed for inserting the sampling device were employed. Our sampling device was made of a flexible material based on filter paper and it is possible to collect certain amount of saliva with sufficient reproducibility by gently putting it on the salivary gland for about 5 seconds. The biosensor measures UA contained in the sampling device by inserting it into the reaction chamber, filled with phosphate buffer saline (PBS). The output current of the biosensor was proportional to the concentration of UA, which contained in the solution collected by the sampling device, from 10 μM – 400 μM. As a real sample test, the biosensor was used for the measurement of UA levels of a healthy male volunteer. The output current increased immediately when the sampling device containing saliva was inserted to the reaction chamber. Concentration of salivary UA was estimated to 150 μM, which value was compatible to the reported UA levels in saliva.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flow Evaluation of Hemolysis Caused by a Miniature Heart Catheter Pump Pattern Recognition and Mixed Reality for Computer-Aided Maxillofacial Surgery and Oncological Assessment Suitable Supervised Machine Learning Techniques For Malignant Mesothelioma Diagnosis Implementation of Asymmetric Kernel Median Filtering for Real-Time Ultrasound Imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1