{"title":"基于kV x射线成像、CBCT和红外相机的幻影定位建模、分析和性能评估","authors":"A. Zhdanov, V. I. Borisov, L. Dorosinsky","doi":"10.1109/ICISCT47635.2019.9012049","DOIUrl":null,"url":null,"abstract":"In this article, we performed the positioning modeling of several phantoms on the VERO radiation device. We used different positioning methods to position several phantoms and checking functionality. As reference phantom, we used pelvic phantom to check the accuracy of the registration algorithm in terms of using bony anatomy information or artificial markers positions. All data and images which were used in this article were taken by the linear accelerator (Linac) of the University Clinic of Erlangen.","PeriodicalId":170576,"journal":{"name":"2019 International Conference on Information Science and Communications Technologies (ICISCT)","volume":"104 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modeling, Analysis and Performance Evaluations of Phantom Positioning by Using kV X-ray Imaging, CBCT, and IR Camera\",\"authors\":\"A. Zhdanov, V. I. Borisov, L. Dorosinsky\",\"doi\":\"10.1109/ICISCT47635.2019.9012049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, we performed the positioning modeling of several phantoms on the VERO radiation device. We used different positioning methods to position several phantoms and checking functionality. As reference phantom, we used pelvic phantom to check the accuracy of the registration algorithm in terms of using bony anatomy information or artificial markers positions. All data and images which were used in this article were taken by the linear accelerator (Linac) of the University Clinic of Erlangen.\",\"PeriodicalId\":170576,\"journal\":{\"name\":\"2019 International Conference on Information Science and Communications Technologies (ICISCT)\",\"volume\":\"104 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Information Science and Communications Technologies (ICISCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISCT47635.2019.9012049\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Information Science and Communications Technologies (ICISCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISCT47635.2019.9012049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modeling, Analysis and Performance Evaluations of Phantom Positioning by Using kV X-ray Imaging, CBCT, and IR Camera
In this article, we performed the positioning modeling of several phantoms on the VERO radiation device. We used different positioning methods to position several phantoms and checking functionality. As reference phantom, we used pelvic phantom to check the accuracy of the registration algorithm in terms of using bony anatomy information or artificial markers positions. All data and images which were used in this article were taken by the linear accelerator (Linac) of the University Clinic of Erlangen.