辐照linde80焊缝金属Mini-C(T)试样试验的实验室间结果和分析

W. Server, M. Sokolov, Masato Yamamoto, R. Carter
{"title":"辐照linde80焊缝金属Mini-C(T)试样试验的实验室间结果和分析","authors":"W. Server, M. Sokolov, Masato Yamamoto, R. Carter","doi":"10.1115/PVP2018-84950","DOIUrl":null,"url":null,"abstract":"An irradiated low-upper-shelf Linde 80 weld metal has been tested by four laboratories as part of an inter-laboratory assessment of use of the miniature compact tension [mini-C(T)] test specimen for Master Curve fracture toughness evaluation following ASTM E1921. The preliminary results from each of the laboratories have been compiled and evaluated together to assess the validity and use of the mini-C(T) specimen for an irradiated reactor pressure vessel material which can exhibit ductile crack growth at low temperatures relative to cleavage initiation fracture toughness. The preliminary results from this mini-C(T) testing can also be compared to extensive specimen test results from larger C(T) specimens of the same irradiated material. Comparisons of the results from each of the laboratories and some inter-laboratory differences in the fracture testing are assessed. The evaluations indicate reasonable agreement between the mini-C(T) and larger specimen results, but the selection of test temperature and the number of test specimens needed to obtain reliable results are more difficult when testing a low-upper-shelf toughness material.","PeriodicalId":128383,"journal":{"name":"Volume 1A: Codes and Standards","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Inter-Laboratory Results and Analyses of Mini-C(T) Specimen Testing of an Irradiated Linde 80 Weld Metal\",\"authors\":\"W. Server, M. Sokolov, Masato Yamamoto, R. Carter\",\"doi\":\"10.1115/PVP2018-84950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An irradiated low-upper-shelf Linde 80 weld metal has been tested by four laboratories as part of an inter-laboratory assessment of use of the miniature compact tension [mini-C(T)] test specimen for Master Curve fracture toughness evaluation following ASTM E1921. The preliminary results from each of the laboratories have been compiled and evaluated together to assess the validity and use of the mini-C(T) specimen for an irradiated reactor pressure vessel material which can exhibit ductile crack growth at low temperatures relative to cleavage initiation fracture toughness. The preliminary results from this mini-C(T) testing can also be compared to extensive specimen test results from larger C(T) specimens of the same irradiated material. Comparisons of the results from each of the laboratories and some inter-laboratory differences in the fracture testing are assessed. The evaluations indicate reasonable agreement between the mini-C(T) and larger specimen results, but the selection of test temperature and the number of test specimens needed to obtain reliable results are more difficult when testing a low-upper-shelf toughness material.\",\"PeriodicalId\":128383,\"journal\":{\"name\":\"Volume 1A: Codes and Standards\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 1A: Codes and Standards\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/PVP2018-84950\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 1A: Codes and Standards","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/PVP2018-84950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

根据ASTM E1921标准,四个实验室对辐照的低上架林德80焊缝金属进行了测试,作为使用微型紧实张力[mini-C(T)]试样进行主曲线断裂韧性评估的实验室间评估的一部分。每个实验室的初步结果已经汇编和评估在一起,以评估迷你c (T)样品的有效性和使用辐照反应堆压力容器材料,该材料可以在低温下表现出相对于解理起始断裂韧性的韧性裂纹扩展。这种小型碳(T)测试的初步结果也可以与相同辐照材料的较大碳(T)样品的广泛样品测试结果进行比较。对每个实验室的结果进行比较,并对实验室间的裂缝测试差异进行评估。评价结果表明,小型c (T)与大型试件结果之间存在合理的一致性,但在测试低上架韧性材料时,获得可靠结果所需的试验温度和试件数量的选择更为困难。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Inter-Laboratory Results and Analyses of Mini-C(T) Specimen Testing of an Irradiated Linde 80 Weld Metal
An irradiated low-upper-shelf Linde 80 weld metal has been tested by four laboratories as part of an inter-laboratory assessment of use of the miniature compact tension [mini-C(T)] test specimen for Master Curve fracture toughness evaluation following ASTM E1921. The preliminary results from each of the laboratories have been compiled and evaluated together to assess the validity and use of the mini-C(T) specimen for an irradiated reactor pressure vessel material which can exhibit ductile crack growth at low temperatures relative to cleavage initiation fracture toughness. The preliminary results from this mini-C(T) testing can also be compared to extensive specimen test results from larger C(T) specimens of the same irradiated material. Comparisons of the results from each of the laboratories and some inter-laboratory differences in the fracture testing are assessed. The evaluations indicate reasonable agreement between the mini-C(T) and larger specimen results, but the selection of test temperature and the number of test specimens needed to obtain reliable results are more difficult when testing a low-upper-shelf toughness material.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improvement of Target Flaw Sizes of CASS Pipe for PD Approval Using PFM Code Preface Effect of Pre-Heat Treatment on Hydrogen Concentration Behavior of y-Grooved Weld Joint Based on a Coupled Analysis of Heat Transfer-Thermal Stress-Hydrogen Diffusion Hydrogen Diffusion Concentration Behaviors for Square Groove Weld Joint Cyclic, Monotonic and Fatigue Performance of Stabilized Stainless Steel in PWR Water and Research Laboratory Interlaboratory Study for Small Punch Testing Preliminary Results
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1