气体腐蚀检测对安防摄像机灰度值的影响

T. Wang
{"title":"气体腐蚀检测对安防摄像机灰度值的影响","authors":"T. Wang","doi":"10.1117/12.2667328","DOIUrl":null,"url":null,"abstract":"The security camera is widely used. With the long-term aging effect of the environment and the increase in service time, its imaging quality will inevitably decrease. However, there are few research on the impact of environmental aging tests on its imaging quality. This article focuses on the gray scale level of image quality. Considering the complexity of the use environment of the camera, the imaging quality of the typical optical imaging system before and after the gas corrosion testing is analyzed. At the same time, the impact of different light source conditions is also considered here. Studies have found that after environmental testing, the gray scale resolution ability of the imaging system decreases. In addition, light source conditions have a greater impact on its gray scale resolution ability. In the case of optical compensation, the gray scale value is significantly reduced, and the camera cannot perform gray scale resolution. In this paper, two test methods, transmitted standard board method and reflective standard board method, are used to analyze the gray scale value. Studies have found that the results of the two methods are self-consistent.","PeriodicalId":227067,"journal":{"name":"International Conference on Precision Instruments and Optical Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The impact of gas corrosion testing on the gray scale value of the security camera\",\"authors\":\"T. Wang\",\"doi\":\"10.1117/12.2667328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The security camera is widely used. With the long-term aging effect of the environment and the increase in service time, its imaging quality will inevitably decrease. However, there are few research on the impact of environmental aging tests on its imaging quality. This article focuses on the gray scale level of image quality. Considering the complexity of the use environment of the camera, the imaging quality of the typical optical imaging system before and after the gas corrosion testing is analyzed. At the same time, the impact of different light source conditions is also considered here. Studies have found that after environmental testing, the gray scale resolution ability of the imaging system decreases. In addition, light source conditions have a greater impact on its gray scale resolution ability. In the case of optical compensation, the gray scale value is significantly reduced, and the camera cannot perform gray scale resolution. In this paper, two test methods, transmitted standard board method and reflective standard board method, are used to analyze the gray scale value. Studies have found that the results of the two methods are self-consistent.\",\"PeriodicalId\":227067,\"journal\":{\"name\":\"International Conference on Precision Instruments and Optical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Precision Instruments and Optical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2667328\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Precision Instruments and Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2667328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

安全摄像头的应用非常广泛。随着环境的长期老化作用和使用时间的增加,其成像质量必然会下降。然而,关于环境老化试验对其成像质量影响的研究很少。本文主要研究图像质量的灰度等级。考虑到摄像机使用环境的复杂性,分析了典型光学成像系统在气体腐蚀测试前后的成像质量。同时,这里还考虑了不同光源条件的影响。研究发现,经过环境测试后,成像系统的灰度分辨能力下降。此外,光源条件对其灰度分辨能力影响较大。在光学补偿的情况下,灰度值明显降低,相机无法进行灰度分辨率。本文采用透射标准板法和反射标准板法两种测试方法对灰度值进行分析。研究发现,两种方法的结果是自洽的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The impact of gas corrosion testing on the gray scale value of the security camera
The security camera is widely used. With the long-term aging effect of the environment and the increase in service time, its imaging quality will inevitably decrease. However, there are few research on the impact of environmental aging tests on its imaging quality. This article focuses on the gray scale level of image quality. Considering the complexity of the use environment of the camera, the imaging quality of the typical optical imaging system before and after the gas corrosion testing is analyzed. At the same time, the impact of different light source conditions is also considered here. Studies have found that after environmental testing, the gray scale resolution ability of the imaging system decreases. In addition, light source conditions have a greater impact on its gray scale resolution ability. In the case of optical compensation, the gray scale value is significantly reduced, and the camera cannot perform gray scale resolution. In this paper, two test methods, transmitted standard board method and reflective standard board method, are used to analyze the gray scale value. Studies have found that the results of the two methods are self-consistent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Light field image array generation for 3D printing image based on backward ray tracing Study on laser degumming and non-destructive technology of rubber press valve Thermal integration analysis of optical machines for space-based laser communications Alignment error correction of five-sensor planar cross magnetic gradient tensor system Research on method of avoiding phase unwrapping error in 3D measurement of gray code
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1