用于闪烁补偿的高功率STATCOM拓扑的基准测试

Hongyang Zhang, L. Angquist, S. Norrga, H. Nee, S. Ostlund
{"title":"用于闪烁补偿的高功率STATCOM拓扑的基准测试","authors":"Hongyang Zhang, L. Angquist, S. Norrga, H. Nee, S. Ostlund","doi":"10.1109/EPE.2016.7695478","DOIUrl":null,"url":null,"abstract":"The current from an electrical arc furnace (EAF) in a steel plant is highly unsymmetrical, i.e. it comprises a large amount of negative sequence. This causes problems with the voltage stability in the capacitor submodules for a static synchronous compensator (STATCOM), when implemented using the modular multilevel converter (M2C) concept. In order to counteract the uncontrollability of the capacitor voltage, a common practice is to circulate a zero-sequence fundamental current or a direct current. The method brings the benefit of re-balancing the active power among the individual phases while it requires over-rating of the valve current or dc voltage of the STATCOM. This would in practice give a more expensive design. This paper presents a benchmark of various M2C-based STATCOM designs considering the valve overrating. The STATCOM topologies will be benchmarked with the EAF modeled for all possible combinations of positive- and negative-sequence current. The rating comparison considering the dc capacitor ripple and zero-sequence harmonic injection are discussed.","PeriodicalId":119358,"journal":{"name":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Benchmark of high-power STATCOM topologies for flicker compensation\",\"authors\":\"Hongyang Zhang, L. Angquist, S. Norrga, H. Nee, S. Ostlund\",\"doi\":\"10.1109/EPE.2016.7695478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The current from an electrical arc furnace (EAF) in a steel plant is highly unsymmetrical, i.e. it comprises a large amount of negative sequence. This causes problems with the voltage stability in the capacitor submodules for a static synchronous compensator (STATCOM), when implemented using the modular multilevel converter (M2C) concept. In order to counteract the uncontrollability of the capacitor voltage, a common practice is to circulate a zero-sequence fundamental current or a direct current. The method brings the benefit of re-balancing the active power among the individual phases while it requires over-rating of the valve current or dc voltage of the STATCOM. This would in practice give a more expensive design. This paper presents a benchmark of various M2C-based STATCOM designs considering the valve overrating. The STATCOM topologies will be benchmarked with the EAF modeled for all possible combinations of positive- and negative-sequence current. The rating comparison considering the dc capacitor ripple and zero-sequence harmonic injection are discussed.\",\"PeriodicalId\":119358,\"journal\":{\"name\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2016.7695478\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2016.7695478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

炼钢厂电弧炉产生的电流是高度不对称的,即由大量负序组成。当使用模块化多电平转换器(M2C)概念实现时,这会导致静态同步补偿器(STATCOM)的电容子模块中的电压稳定性问题。为了抵消电容器电压的不可控性,通常的做法是使零序基波电流或直流电流循环。该方法的优点是在各相之间重新平衡有功功率,但需要高估STATCOM的阀电流或直流电压。在实践中,这将带来更昂贵的设计。本文给出了考虑阀值过高的基于m2c的各种STATCOM设计的基准。STATCOM拓扑将与EAF模型进行基准测试,以适应所有可能的正序和负序电流组合。讨论了考虑直流电容纹波和零序谐波注入的额定值比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Benchmark of high-power STATCOM topologies for flicker compensation
The current from an electrical arc furnace (EAF) in a steel plant is highly unsymmetrical, i.e. it comprises a large amount of negative sequence. This causes problems with the voltage stability in the capacitor submodules for a static synchronous compensator (STATCOM), when implemented using the modular multilevel converter (M2C) concept. In order to counteract the uncontrollability of the capacitor voltage, a common practice is to circulate a zero-sequence fundamental current or a direct current. The method brings the benefit of re-balancing the active power among the individual phases while it requires over-rating of the valve current or dc voltage of the STATCOM. This would in practice give a more expensive design. This paper presents a benchmark of various M2C-based STATCOM designs considering the valve overrating. The STATCOM topologies will be benchmarked with the EAF modeled for all possible combinations of positive- and negative-sequence current. The rating comparison considering the dc capacitor ripple and zero-sequence harmonic injection are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Continuous control set space vector modulation for the 3×3 direct matrix converter Connector-less SiC power modules with integrated shunt — Low-profile design for low inductance and low cost DC microgrid power coordination based on fuzzy logic control Design and implementation of magnetron power supply and emulator Virtual synchronous-machine control of voltage-source converters in a low-voltage microgrid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1