{"title":"电力配电网电压暂降分析实例研究","authors":"N.A. Bakar, A. Mohamed, M. Ismail","doi":"10.1109/PECON.2003.1437468","DOIUrl":null,"url":null,"abstract":"Voltage sags are momentary dips in voltage magnitude that can cause sensitive equipments to trip. Such occurrences have a major economic impact and therefore, the study of voltage sag has become a major effort worldwide. This paper presents a voltage sag analysis implemented on an actual distribution system. The objective of the study presented in this paper is to develop a suitable method for voltage sag analysis in which the method is demonstrated on a practical distribution system. The voltage sag analysis is performed using the commercial software PSS/ADEPT for performing load flow and short circuit simulations. The distribution network is modeled using the actual network data and the transmission system is considered as a source. Faults are introduced at various points in the system, at the buses and along the lines. Simulation results are presented in the form of voltage sag vulnerability areas.","PeriodicalId":136640,"journal":{"name":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A case study of voltage sag analysis in a utility distribution system\",\"authors\":\"N.A. Bakar, A. Mohamed, M. Ismail\",\"doi\":\"10.1109/PECON.2003.1437468\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage sags are momentary dips in voltage magnitude that can cause sensitive equipments to trip. Such occurrences have a major economic impact and therefore, the study of voltage sag has become a major effort worldwide. This paper presents a voltage sag analysis implemented on an actual distribution system. The objective of the study presented in this paper is to develop a suitable method for voltage sag analysis in which the method is demonstrated on a practical distribution system. The voltage sag analysis is performed using the commercial software PSS/ADEPT for performing load flow and short circuit simulations. The distribution network is modeled using the actual network data and the transmission system is considered as a source. Faults are introduced at various points in the system, at the buses and along the lines. Simulation results are presented in the form of voltage sag vulnerability areas.\",\"PeriodicalId\":136640,\"journal\":{\"name\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"volume\":\"73 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. National Power Engineering Conference, 2003. PECon 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2003.1437468\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2003.1437468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A case study of voltage sag analysis in a utility distribution system
Voltage sags are momentary dips in voltage magnitude that can cause sensitive equipments to trip. Such occurrences have a major economic impact and therefore, the study of voltage sag has become a major effort worldwide. This paper presents a voltage sag analysis implemented on an actual distribution system. The objective of the study presented in this paper is to develop a suitable method for voltage sag analysis in which the method is demonstrated on a practical distribution system. The voltage sag analysis is performed using the commercial software PSS/ADEPT for performing load flow and short circuit simulations. The distribution network is modeled using the actual network data and the transmission system is considered as a source. Faults are introduced at various points in the system, at the buses and along the lines. Simulation results are presented in the form of voltage sag vulnerability areas.