{"title":"一种用于非接触式心跳检测和HRV提取的可调频率系统","authors":"D. Obeid, S. Sadek, G. Zaharia, G. El Zein","doi":"10.1109/ISSCS.2009.5206132","DOIUrl":null,"url":null,"abstract":"This paper presents a practical study for heartbeat detection at 1 m distance. Our microwave system, based on a vector network analyzer, is used at 2.4 GHz, 5.8 GHz, 10 GHz, 16 GHz, and 60 GHz. Heart Rate Variability is extracted from the time domain variation of the phase of S21 for both the original and the smoothed signal, and its standard deviation is calculated.","PeriodicalId":277587,"journal":{"name":"2009 International Symposium on Signals, Circuits and Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A tunable-frequency system for touch-less heartbeat detection and HRV extraction\",\"authors\":\"D. Obeid, S. Sadek, G. Zaharia, G. El Zein\",\"doi\":\"10.1109/ISSCS.2009.5206132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a practical study for heartbeat detection at 1 m distance. Our microwave system, based on a vector network analyzer, is used at 2.4 GHz, 5.8 GHz, 10 GHz, 16 GHz, and 60 GHz. Heart Rate Variability is extracted from the time domain variation of the phase of S21 for both the original and the smoothed signal, and its standard deviation is calculated.\",\"PeriodicalId\":277587,\"journal\":{\"name\":\"2009 International Symposium on Signals, Circuits and Systems\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Symposium on Signals, Circuits and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISSCS.2009.5206132\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Symposium on Signals, Circuits and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCS.2009.5206132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A tunable-frequency system for touch-less heartbeat detection and HRV extraction
This paper presents a practical study for heartbeat detection at 1 m distance. Our microwave system, based on a vector network analyzer, is used at 2.4 GHz, 5.8 GHz, 10 GHz, 16 GHz, and 60 GHz. Heart Rate Variability is extracted from the time domain variation of the phase of S21 for both the original and the smoothed signal, and its standard deviation is calculated.