电力系统无功仿真与控制

Walter L. Snyder
{"title":"电力系统无功仿真与控制","authors":"Walter L. Snyder","doi":"10.1109/CDC.1984.272420","DOIUrl":null,"url":null,"abstract":"This paper describes reactive power (var) flow and its effect on power system control and operation. In particular, an Automatic Var Control computer program is described which is being implemented in the Energy Control Center of a Canadian utility. This program will send control signals to power system devices in order to eliminate or at least minimize voltage violations. The control devices include generating units, transformers, and shunt capacitors. A linear programming algorithm is employed to determine the amount and placement of control action based on linearized incremental relationships between voltage and var flow.","PeriodicalId":269680,"journal":{"name":"The 23rd IEEE Conference on Decision and Control","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1984-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reactive power simulation and control for electric utilities\",\"authors\":\"Walter L. Snyder\",\"doi\":\"10.1109/CDC.1984.272420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes reactive power (var) flow and its effect on power system control and operation. In particular, an Automatic Var Control computer program is described which is being implemented in the Energy Control Center of a Canadian utility. This program will send control signals to power system devices in order to eliminate or at least minimize voltage violations. The control devices include generating units, transformers, and shunt capacitors. A linear programming algorithm is employed to determine the amount and placement of control action based on linearized incremental relationships between voltage and var flow.\",\"PeriodicalId\":269680,\"journal\":{\"name\":\"The 23rd IEEE Conference on Decision and Control\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 23rd IEEE Conference on Decision and Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CDC.1984.272420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 23rd IEEE Conference on Decision and Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CDC.1984.272420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了无功潮流及其对电力系统控制和运行的影响。特别地,描述了一种在加拿大某公用事业公司能源控制中心实施的自动无功控制计算机程序。该程序将向电力系统设备发送控制信号,以消除或至少最小化电压违例。控制装置包括发电机组、变压器和并联电容器。基于电压和无功流量之间的线性增量关系,采用线性规划算法确定控制动作的数量和位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reactive power simulation and control for electric utilities
This paper describes reactive power (var) flow and its effect on power system control and operation. In particular, an Automatic Var Control computer program is described which is being implemented in the Energy Control Center of a Canadian utility. This program will send control signals to power system devices in order to eliminate or at least minimize voltage violations. The control devices include generating units, transformers, and shunt capacitors. A linear programming algorithm is employed to determine the amount and placement of control action based on linearized incremental relationships between voltage and var flow.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Adaptive implementation of the internal model principle Fuzzy parking control of model car Stochastic control of a partially observed linear stochastic system with an exponential-of-integral performance index Structures for nonlinear systems Reducing cluster size for computing remedial adjustments for voltage and loading violations on the power system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1