A. Sokolov, A. Pchelintsev, A. Loupilov, V. A. Zalinkevich, A. Lapenas
{"title":"用于监测辐射核素的x射线光谱仪","authors":"A. Sokolov, A. Pchelintsev, A. Loupilov, V. A. Zalinkevich, A. Lapenas","doi":"10.1109/NSSMIC.2001.1009662","DOIUrl":null,"url":null,"abstract":"The design and characteristics of the spectrometer for beta-particles and conversional electrons in the energy range from 15 to 3000 keV and X-ray radiation from 2 to 60 keV are presented. Radiation registration is executed by SiLi detector with sensitive area of 500 mm/sup 2/ and thickness of 4.5 mm. The energy resolution for conversional electrons with energy 624 keV were found to be 2.0 keV and X-ray with energy 5.9 keV were found to be 280 eV.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Beta and X-ray spectrometer for monitoring of beta-radiating nuclides\",\"authors\":\"A. Sokolov, A. Pchelintsev, A. Loupilov, V. A. Zalinkevich, A. Lapenas\",\"doi\":\"10.1109/NSSMIC.2001.1009662\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The design and characteristics of the spectrometer for beta-particles and conversional electrons in the energy range from 15 to 3000 keV and X-ray radiation from 2 to 60 keV are presented. Radiation registration is executed by SiLi detector with sensitive area of 500 mm/sup 2/ and thickness of 4.5 mm. The energy resolution for conversional electrons with energy 624 keV were found to be 2.0 keV and X-ray with energy 5.9 keV were found to be 280 eV.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1009662\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1009662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Beta and X-ray spectrometer for monitoring of beta-radiating nuclides
The design and characteristics of the spectrometer for beta-particles and conversional electrons in the energy range from 15 to 3000 keV and X-ray radiation from 2 to 60 keV are presented. Radiation registration is executed by SiLi detector with sensitive area of 500 mm/sup 2/ and thickness of 4.5 mm. The energy resolution for conversional electrons with energy 624 keV were found to be 2.0 keV and X-ray with energy 5.9 keV were found to be 280 eV.