{"title":"脉冲负载下主动控制混合直流微电网的性能增强","authors":"M. Farhadi, O. Mohammed","doi":"10.1109/IAS.2014.6978471","DOIUrl":null,"url":null,"abstract":"In this paper, a new energy control scheme is proposed for actively controlled hybrid dc microgrid to reduce the adverse impact of pulsed power loads. The proposed energy control is an adaptive current-voltage control (ACVC) scheme based on the moving average measurement technique and an adaptive proportional compensator. Unlike conventional energy control methods, the proposed ACVC approach has the advantages of controlling both voltage and current of the system while it keep the output current of the power converter at a relatively constant value. For this study, a laboratory scale hybrid dc microgrid is developed to evaluate the performance of the ACVC strategy and to compare its performance with the other conventional energy control methods. Using experimental test results, it is shown that the proposed strategy highly improves the dynamic performance of the hybrid dc microgrid. Although the ACVC technique causes slightly more bus voltage variation, it effectively eliminates the high current and power pulsation of the power converters. The experimental test results for different pulse duty ratios demonstrated a significant improvement achieved by the developed ACVC scheme in enhancing the system efficiency, reducing the ac grid voltage drop and the frequency fluctuations.","PeriodicalId":446068,"journal":{"name":"2014 IEEE Industry Application Society Annual Meeting","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Performance enhancement of actively controlled hybrid DC microgrid with pulsed load\",\"authors\":\"M. Farhadi, O. Mohammed\",\"doi\":\"10.1109/IAS.2014.6978471\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new energy control scheme is proposed for actively controlled hybrid dc microgrid to reduce the adverse impact of pulsed power loads. The proposed energy control is an adaptive current-voltage control (ACVC) scheme based on the moving average measurement technique and an adaptive proportional compensator. Unlike conventional energy control methods, the proposed ACVC approach has the advantages of controlling both voltage and current of the system while it keep the output current of the power converter at a relatively constant value. For this study, a laboratory scale hybrid dc microgrid is developed to evaluate the performance of the ACVC strategy and to compare its performance with the other conventional energy control methods. Using experimental test results, it is shown that the proposed strategy highly improves the dynamic performance of the hybrid dc microgrid. Although the ACVC technique causes slightly more bus voltage variation, it effectively eliminates the high current and power pulsation of the power converters. The experimental test results for different pulse duty ratios demonstrated a significant improvement achieved by the developed ACVC scheme in enhancing the system efficiency, reducing the ac grid voltage drop and the frequency fluctuations.\",\"PeriodicalId\":446068,\"journal\":{\"name\":\"2014 IEEE Industry Application Society Annual Meeting\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Industry Application Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2014.6978471\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Industry Application Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2014.6978471","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

本文提出了一种新的主动控制混合直流微电网的能量控制方案,以减少脉冲功率负载的不利影响。提出的能量控制是一种基于移动平均测量技术和自适应比例补偿器的自适应电流电压控制(ACVC)方案。与传统的能量控制方法不同,所提出的ACVC方法具有控制系统电压和电流的优点,同时使功率变换器的输出电流保持在一个相对恒定的值。在本研究中,开发了一个实验室规模的混合直流微电网,以评估ACVC策略的性能,并将其与其他常规能量控制方法的性能进行比较。实验测试结果表明,该策略能有效地改善混合直流微电网的动态性能。虽然ACVC技术引起的母线电压变化略大,但它有效地消除了功率变换器的大电流和功率脉动。不同脉冲占空比下的实验测试结果表明,所提出的ACVC方案在提高系统效率、减小交流电网电压降和频率波动方面有显著改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance enhancement of actively controlled hybrid DC microgrid with pulsed load
In this paper, a new energy control scheme is proposed for actively controlled hybrid dc microgrid to reduce the adverse impact of pulsed power loads. The proposed energy control is an adaptive current-voltage control (ACVC) scheme based on the moving average measurement technique and an adaptive proportional compensator. Unlike conventional energy control methods, the proposed ACVC approach has the advantages of controlling both voltage and current of the system while it keep the output current of the power converter at a relatively constant value. For this study, a laboratory scale hybrid dc microgrid is developed to evaluate the performance of the ACVC strategy and to compare its performance with the other conventional energy control methods. Using experimental test results, it is shown that the proposed strategy highly improves the dynamic performance of the hybrid dc microgrid. Although the ACVC technique causes slightly more bus voltage variation, it effectively eliminates the high current and power pulsation of the power converters. The experimental test results for different pulse duty ratios demonstrated a significant improvement achieved by the developed ACVC scheme in enhancing the system efficiency, reducing the ac grid voltage drop and the frequency fluctuations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Advancements in vibration monitoring for the mining industry Real time benefit computation for electric distribution system automation and control A web-based communication module design of a real-time multi-sensor fire detection and notification system Analysis of PEV charging impact on distribution transformer aging for charging station transformer design Simplified models of LED ballasts for spice
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1