口腔防护型生物传感器“穴式传感器”用于唾液葡萄糖遥测系统的监测

T. Arakawa, Yusuke Kuroki, Hiroki Nitta, Koji Toma, K. Mitsubayashi, Shuhei Takeuchi, T. Sekita, S. Minakuchi
{"title":"口腔防护型生物传感器“穴式传感器”用于唾液葡萄糖遥测系统的监测","authors":"T. Arakawa, Yusuke Kuroki, Hiroki Nitta, Koji Toma, K. Mitsubayashi, Shuhei Takeuchi, T. Sekita, S. Minakuchi","doi":"10.1109/ICSENST.2015.7438362","DOIUrl":null,"url":null,"abstract":"We have developed detachable “Cavitas sensors” into human cavitas sites of oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor based on the integration of Pt and Ag/AgCl electrodes with an enzyme membrane on a mouth guard was developed and tested. This mouth guard type biosensor was integrated with a glucose sensor and wireless measurement system. The electrodes were formed on the mouth guard surface which made of a polyethylene terephthalate glycol (PETG). The Pt working electrode was coated with the glucose oxidase (GOD) membrane. In the investigation of in-vitro characterization, the biosensor showed excellent relationship between the output current and the glucose concentration. In artificial saliva consisting of salts and proteins, the glucose sensor exhibits high-sensitive detection in a range of 5-1000 μmol/L. We demonstrated the capability of the sensor and wireless communication module to characterize an inclusion in oral phantom that imitative structure of human oral cavity. Stable and long-term monitoring (more than 2 hours) using telemetry system was established. The mouth guard biosensor would be useful for real-time and non-invasive method as a novel health care management.","PeriodicalId":375376,"journal":{"name":"2015 9th International Conference on Sensing Technology (ICST)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Mouth guard type biosensor “cavitous sensor” for monitoring of saliva glucose with telemetry system\",\"authors\":\"T. Arakawa, Yusuke Kuroki, Hiroki Nitta, Koji Toma, K. Mitsubayashi, Shuhei Takeuchi, T. Sekita, S. Minakuchi\",\"doi\":\"10.1109/ICSENST.2015.7438362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed detachable “Cavitas sensors” into human cavitas sites of oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor based on the integration of Pt and Ag/AgCl electrodes with an enzyme membrane on a mouth guard was developed and tested. This mouth guard type biosensor was integrated with a glucose sensor and wireless measurement system. The electrodes were formed on the mouth guard surface which made of a polyethylene terephthalate glycol (PETG). The Pt working electrode was coated with the glucose oxidase (GOD) membrane. In the investigation of in-vitro characterization, the biosensor showed excellent relationship between the output current and the glucose concentration. In artificial saliva consisting of salts and proteins, the glucose sensor exhibits high-sensitive detection in a range of 5-1000 μmol/L. We demonstrated the capability of the sensor and wireless communication module to characterize an inclusion in oral phantom that imitative structure of human oral cavity. Stable and long-term monitoring (more than 2 hours) using telemetry system was established. The mouth guard biosensor would be useful for real-time and non-invasive method as a novel health care management.\",\"PeriodicalId\":375376,\"journal\":{\"name\":\"2015 9th International Conference on Sensing Technology (ICST)\",\"volume\":\"55 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 9th International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2015.7438362\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2015.7438362","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

我们开发了可拆卸的“腔体传感器”,可植入人口腔腔体部位,用于无创监测唾液葡萄糖。研制了一种基于Pt和Ag/AgCl电极与酶膜结合的唾液生物传感器。该口腔防护型生物传感器集成了葡萄糖传感器和无线测量系统。电极形成在由聚对苯二甲酸乙二醇酯(PETG)制成的口腔防护表面。在铂工作电极上包被葡萄糖氧化酶(GOD)膜。在体外表征的研究中,该生物传感器显示出输出电流与葡萄糖浓度之间良好的关系。在含盐和蛋白质的人工唾液中,葡萄糖传感器在5 ~ 1000 μmol/L范围内具有较高的检测灵敏度。我们展示了传感器和无线通信模块的能力,以表征包含在口腔幻影,模仿人类口腔结构。建立了长期稳定监测(2小时以上)的遥测系统。口腔防护生物传感器是一种实时、无创的新型医疗管理方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mouth guard type biosensor “cavitous sensor” for monitoring of saliva glucose with telemetry system
We have developed detachable “Cavitas sensors” into human cavitas sites of oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor based on the integration of Pt and Ag/AgCl electrodes with an enzyme membrane on a mouth guard was developed and tested. This mouth guard type biosensor was integrated with a glucose sensor and wireless measurement system. The electrodes were formed on the mouth guard surface which made of a polyethylene terephthalate glycol (PETG). The Pt working electrode was coated with the glucose oxidase (GOD) membrane. In the investigation of in-vitro characterization, the biosensor showed excellent relationship between the output current and the glucose concentration. In artificial saliva consisting of salts and proteins, the glucose sensor exhibits high-sensitive detection in a range of 5-1000 μmol/L. We demonstrated the capability of the sensor and wireless communication module to characterize an inclusion in oral phantom that imitative structure of human oral cavity. Stable and long-term monitoring (more than 2 hours) using telemetry system was established. The mouth guard biosensor would be useful for real-time and non-invasive method as a novel health care management.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The development and evaluation of an arm usage coach for Stroke survivors Uncertainty analysis of a vibrating-wire system for magnetic axes localization Magnetic field shaping for improved 1-D linear position measurement Real-time detection of residual antibiotics concentration with microwave cavity and planar EM sensors Ambient temperature effect on Amorphous Silicon (A-Si) Photovoltaic module using sensing technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1