S. Miroshnychenko, A. Nevgasymyy, S. Senchurov, O. Motolyga, Khrystyna Faryna
{"title":"数字断层合成中用于重建质量控制的模拟幻影投影","authors":"S. Miroshnychenko, A. Nevgasymyy, S. Senchurov, O. Motolyga, Khrystyna Faryna","doi":"10.1109/ELNANO.2018.8477526","DOIUrl":null,"url":null,"abstract":"IMASIM software was used to generate sets of X-ray projections for quality control in digital tomosynthesis. Corresponding projections of a polymethylmethacrylate(PMMA) phantom with the same size were taken using x-ray tomosynthesis imaging equipment. A specially designed fiduciary marker bead phantom was used to measure the relative positions of imaging system elements. A good correspondence was found between real and simulated projections and reconstructed slices. The ability to create simulated projections with predefined imperfections gives valuable benefits to analysis of overall tomosynthesis performance.","PeriodicalId":269665,"journal":{"name":"2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulated Phantom Projections for Reconstruction Quality Control in Digital Tomosynthesis\",\"authors\":\"S. Miroshnychenko, A. Nevgasymyy, S. Senchurov, O. Motolyga, Khrystyna Faryna\",\"doi\":\"10.1109/ELNANO.2018.8477526\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IMASIM software was used to generate sets of X-ray projections for quality control in digital tomosynthesis. Corresponding projections of a polymethylmethacrylate(PMMA) phantom with the same size were taken using x-ray tomosynthesis imaging equipment. A specially designed fiduciary marker bead phantom was used to measure the relative positions of imaging system elements. A good correspondence was found between real and simulated projections and reconstructed slices. The ability to create simulated projections with predefined imperfections gives valuable benefits to analysis of overall tomosynthesis performance.\",\"PeriodicalId\":269665,\"journal\":{\"name\":\"2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO)\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELNANO.2018.8477526\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 38th International Conference on Electronics and Nanotechnology (ELNANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELNANO.2018.8477526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simulated Phantom Projections for Reconstruction Quality Control in Digital Tomosynthesis
IMASIM software was used to generate sets of X-ray projections for quality control in digital tomosynthesis. Corresponding projections of a polymethylmethacrylate(PMMA) phantom with the same size were taken using x-ray tomosynthesis imaging equipment. A specially designed fiduciary marker bead phantom was used to measure the relative positions of imaging system elements. A good correspondence was found between real and simulated projections and reconstructed slices. The ability to create simulated projections with predefined imperfections gives valuable benefits to analysis of overall tomosynthesis performance.