SPECT乳房成像使用更接近完整的轨道和结合针孔-平行光束准直

J. Bowsher, M. Tornai, S. Metzler, J. Peter, R. Jaszczak
{"title":"SPECT乳房成像使用更接近完整的轨道和结合针孔-平行光束准直","authors":"J. Bowsher, M. Tornai, S. Metzler, J. Peter, R. Jaszczak","doi":"10.1109/NSSMIC.2001.1008582","DOIUrl":null,"url":null,"abstract":"Two novel pinhole orbits for SPECT breast imaging are investigated using noise-free analytically simulated projection data. The two orbits are designed to more nearly completely sample the breast region while also maintaining close proximity of the pinhole to the breast. The two orbits involve the same trajectory but different angular orientations for the pinhole. For both orbits the pinhole traverses two half circles, which from an anterior perspective thus appear to have the shape of an \"X\". The orbits differ in that in one case the pinhole is tilted toward a single point throughout the orbit whereas in the other case it is untilted. It is found that both orbits remove the distortions characteristic of purely transverse, single-half-circle orbits. Also investigated is the use of parallel-beam collimators on the remaining cameras of triple-headed SPECT scanners. It is found that these additional parallel-beam measurements greatly improve estimates of torso activity. Determining whether parallel-beam measurements improve estimates of breast activity will require additional studies involving clinical levels of noise in the projection data.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"SPECT breast imaging using more nearly complete orbits and combined pinhole-parallel-beam collimation\",\"authors\":\"J. Bowsher, M. Tornai, S. Metzler, J. Peter, R. Jaszczak\",\"doi\":\"10.1109/NSSMIC.2001.1008582\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two novel pinhole orbits for SPECT breast imaging are investigated using noise-free analytically simulated projection data. The two orbits are designed to more nearly completely sample the breast region while also maintaining close proximity of the pinhole to the breast. The two orbits involve the same trajectory but different angular orientations for the pinhole. For both orbits the pinhole traverses two half circles, which from an anterior perspective thus appear to have the shape of an \\\"X\\\". The orbits differ in that in one case the pinhole is tilted toward a single point throughout the orbit whereas in the other case it is untilted. It is found that both orbits remove the distortions characteristic of purely transverse, single-half-circle orbits. Also investigated is the use of parallel-beam collimators on the remaining cameras of triple-headed SPECT scanners. It is found that these additional parallel-beam measurements greatly improve estimates of torso activity. Determining whether parallel-beam measurements improve estimates of breast activity will require additional studies involving clinical levels of noise in the projection data.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1008582\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008582","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

利用无噪声分析模拟投影数据,研究了两种用于SPECT乳腺成像的新型针孔轨道。这两个轨道的设计是为了更接近完全地采样乳房区域,同时也保持针孔与乳房的近距离。这两个轨道包含相同的轨迹,但针孔的角度方向不同。对于这两个轨道,针孔穿过两个半圆,从前面的角度来看,这似乎是一个“X”的形状。轨道的不同之处在于,在一种情况下,针孔在整个轨道上向一个点倾斜,而在另一种情况下,它是不倾斜的。发现两种轨道都消除了纯横向、单半圆轨道的畸变特征。还研究了平行光束准直器在三头SPECT扫描仪的剩余相机上的使用。发现这些额外的平行光束测量大大提高了躯干活动的估计。确定平行光束测量是否能改善对乳房活动的估计,还需要对投影数据中的临床噪声水平进行额外的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SPECT breast imaging using more nearly complete orbits and combined pinhole-parallel-beam collimation
Two novel pinhole orbits for SPECT breast imaging are investigated using noise-free analytically simulated projection data. The two orbits are designed to more nearly completely sample the breast region while also maintaining close proximity of the pinhole to the breast. The two orbits involve the same trajectory but different angular orientations for the pinhole. For both orbits the pinhole traverses two half circles, which from an anterior perspective thus appear to have the shape of an "X". The orbits differ in that in one case the pinhole is tilted toward a single point throughout the orbit whereas in the other case it is untilted. It is found that both orbits remove the distortions characteristic of purely transverse, single-half-circle orbits. Also investigated is the use of parallel-beam collimators on the remaining cameras of triple-headed SPECT scanners. It is found that these additional parallel-beam measurements greatly improve estimates of torso activity. Determining whether parallel-beam measurements improve estimates of breast activity will require additional studies involving clinical levels of noise in the projection data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of IEC and IEEE standards for computer-based control systems important to safety Helicity-correlated systematics for SLAC Experiment E158 Achievements of the ASTRO-E Hard X-ray Detector development Inexpensive position sensitive detector block for 40 mm diameter PMT using quadrant sharing configuration A /sup 252/Cf neutron irradiator for testing electronic components for the Large Hadron Collider
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1