{"title":"复杂心脏消融任务连续统机器人的自主控制","authors":"Michael C. Yip, Jake Sganga, David B. Camarillo","doi":"10.1142/S2424905X17500027","DOIUrl":null,"url":null,"abstract":"Continuum manipulators enable minimally-invasive surgery on the beating heart, but the challenges involved in manually controlling the manipulator’s tip position and contact force with the tissue result in failed procedures and complications. The objective of this work is to achieve autonomous robotic control of a continuum manipulator’s position and force in a beating heart model. We present a model-less hybrid control approach that regulates the tip position/force of manipulators with unknown kinematics/mechanics, under unknown constraints along the manipulator’s body. The algorithms estimate the Jacobian in the presence of heartbeat disturbances and sensor noise in real time, enabling closed-loop control. Using this model-less control approach, a robotic catheter autonomously traced clinically relevant paths on a simulated beating heart environment while regulating contact force. A gating procedure is used to tighten the treatment margins and improve precision. Experimental results demonstrate the capabilities of the robot (1.4±1.1mm–1.9±1.4mm tracking error) while user demonstrations show the difficulty of manually performing the same task (2.6±2.0mm–4.3±3.9mm tracking error). This new, robotically-enabled contiguous ablation method could reduce ablation path discontinuities, improve consistency of treatment, and therefore improve clinical outcomes.","PeriodicalId":447761,"journal":{"name":"J. Medical Robotics Res.","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":"{\"title\":\"Autonomous Control of Continuum Robot Manipulators for Complex Cardiac Ablation Tasks\",\"authors\":\"Michael C. Yip, Jake Sganga, David B. Camarillo\",\"doi\":\"10.1142/S2424905X17500027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Continuum manipulators enable minimally-invasive surgery on the beating heart, but the challenges involved in manually controlling the manipulator’s tip position and contact force with the tissue result in failed procedures and complications. The objective of this work is to achieve autonomous robotic control of a continuum manipulator’s position and force in a beating heart model. We present a model-less hybrid control approach that regulates the tip position/force of manipulators with unknown kinematics/mechanics, under unknown constraints along the manipulator’s body. The algorithms estimate the Jacobian in the presence of heartbeat disturbances and sensor noise in real time, enabling closed-loop control. Using this model-less control approach, a robotic catheter autonomously traced clinically relevant paths on a simulated beating heart environment while regulating contact force. A gating procedure is used to tighten the treatment margins and improve precision. Experimental results demonstrate the capabilities of the robot (1.4±1.1mm–1.9±1.4mm tracking error) while user demonstrations show the difficulty of manually performing the same task (2.6±2.0mm–4.3±3.9mm tracking error). This new, robotically-enabled contiguous ablation method could reduce ablation path discontinuities, improve consistency of treatment, and therefore improve clinical outcomes.\",\"PeriodicalId\":447761,\"journal\":{\"name\":\"J. Medical Robotics Res.\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"34\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"J. Medical Robotics Res.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/S2424905X17500027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"J. Medical Robotics Res.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S2424905X17500027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Autonomous Control of Continuum Robot Manipulators for Complex Cardiac Ablation Tasks
Continuum manipulators enable minimally-invasive surgery on the beating heart, but the challenges involved in manually controlling the manipulator’s tip position and contact force with the tissue result in failed procedures and complications. The objective of this work is to achieve autonomous robotic control of a continuum manipulator’s position and force in a beating heart model. We present a model-less hybrid control approach that regulates the tip position/force of manipulators with unknown kinematics/mechanics, under unknown constraints along the manipulator’s body. The algorithms estimate the Jacobian in the presence of heartbeat disturbances and sensor noise in real time, enabling closed-loop control. Using this model-less control approach, a robotic catheter autonomously traced clinically relevant paths on a simulated beating heart environment while regulating contact force. A gating procedure is used to tighten the treatment margins and improve precision. Experimental results demonstrate the capabilities of the robot (1.4±1.1mm–1.9±1.4mm tracking error) while user demonstrations show the difficulty of manually performing the same task (2.6±2.0mm–4.3±3.9mm tracking error). This new, robotically-enabled contiguous ablation method could reduce ablation path discontinuities, improve consistency of treatment, and therefore improve clinical outcomes.