全血图像斑点分析的应用

D. Chicea
{"title":"全血图像斑点分析的应用","authors":"D. Chicea","doi":"10.1117/12.801934","DOIUrl":null,"url":null,"abstract":"When coherent light is incident upon an optically thick biological fluid having scattering centers (SC) in suspension, like whole blood, the backscattered light can be recorded, resulting an image speckle. A program was written to extract the time series from each pixel of the CDD conversion matrix. The autocorrelation time of the series was calculated and the autocorrelation time was determined on blood samples from different human subjects. The autocorrelation time was analyzed and compared with the erythrocyte sedimentation rate (ESR) measured during a standard laboratory test using the modified Westergren method. A different procedure to record the time series, using a detector and a data acquisition system was used as well and the autocorrelation time was calculated for the time series recorded using this procedure. The results of the work performed so far indicate that the two properties appear to be slightly correlated. A fast procedure for assessing the ESR is suggested.","PeriodicalId":390439,"journal":{"name":"Industrial Laser Applications: INDLAS","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of whole blood image speckle analysis\",\"authors\":\"D. Chicea\",\"doi\":\"10.1117/12.801934\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When coherent light is incident upon an optically thick biological fluid having scattering centers (SC) in suspension, like whole blood, the backscattered light can be recorded, resulting an image speckle. A program was written to extract the time series from each pixel of the CDD conversion matrix. The autocorrelation time of the series was calculated and the autocorrelation time was determined on blood samples from different human subjects. The autocorrelation time was analyzed and compared with the erythrocyte sedimentation rate (ESR) measured during a standard laboratory test using the modified Westergren method. A different procedure to record the time series, using a detector and a data acquisition system was used as well and the autocorrelation time was calculated for the time series recorded using this procedure. The results of the work performed so far indicate that the two properties appear to be slightly correlated. A fast procedure for assessing the ESR is suggested.\",\"PeriodicalId\":390439,\"journal\":{\"name\":\"Industrial Laser Applications: INDLAS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Industrial Laser Applications: INDLAS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.801934\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial Laser Applications: INDLAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.801934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

当相干光入射到具有悬浮散射中心(SC)的光学厚度的生物流体(如全血)上时,可以记录背散射光,从而产生图像散斑。编写了从CDD转换矩阵的每个像素提取时间序列的程序。计算了该序列的自相关时间,并测定了不同受试者血液样本的自相关时间。分析了自相关时间,并与使用改进的Westergren方法在标准实验室测试中测量的红细胞沉降率(ESR)进行了比较。使用检测器和数据采集系统记录时间序列也使用了不同的程序,并计算了使用该程序记录的时间序列的自相关时间。迄今为止所进行的工作结果表明,这两种性质似乎有轻微的相关性。提出了一种快速评估ESR的程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of whole blood image speckle analysis
When coherent light is incident upon an optically thick biological fluid having scattering centers (SC) in suspension, like whole blood, the backscattered light can be recorded, resulting an image speckle. A program was written to extract the time series from each pixel of the CDD conversion matrix. The autocorrelation time of the series was calculated and the autocorrelation time was determined on blood samples from different human subjects. The autocorrelation time was analyzed and compared with the erythrocyte sedimentation rate (ESR) measured during a standard laboratory test using the modified Westergren method. A different procedure to record the time series, using a detector and a data acquisition system was used as well and the autocorrelation time was calculated for the time series recorded using this procedure. The results of the work performed so far indicate that the two properties appear to be slightly correlated. A fast procedure for assessing the ESR is suggested.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the manufacturability of MMC threads by means of laser technology New optics for industrial laser applications: VariSpot and VariFoc Laser heat treatment of welds for various stainless steels Laser removal of thin layers for surface cleaning CHODIN-a computer code to simulate coherent light scattering dynamics on biological suspensions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1