旨在减少损失的UPQC补偿策略和设计

R. Faranda, I. Valadè
{"title":"旨在减少损失的UPQC补偿策略和设计","authors":"R. Faranda, I. Valadè","doi":"10.1109/ISIE.2002.1025971","DOIUrl":null,"url":null,"abstract":"After showing how the UPQC is able to-compensate for network voltage variations through different operating strategies, one such strategy is proposed whose aim is to limit the total losses of the device. An estimate was made of the extent of the losses of converters as a function of the DC section voltage and of the maximum injectable voltage from the injection transformer and, subsequently, with reference to a specific case, the optimal values for the design of the device are defined. A procedure is proposed, based on simulation of the behaviour of converters, in order to calculate the operating losses of inverters controlled in accordance with the two different PWM techniques used in controlling valves of the device in question.","PeriodicalId":330283,"journal":{"name":"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"62","resultStr":"{\"title\":\"UPQC compensation strategy and design aimed at reducing losses\",\"authors\":\"R. Faranda, I. Valadè\",\"doi\":\"10.1109/ISIE.2002.1025971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"After showing how the UPQC is able to-compensate for network voltage variations through different operating strategies, one such strategy is proposed whose aim is to limit the total losses of the device. An estimate was made of the extent of the losses of converters as a function of the DC section voltage and of the maximum injectable voltage from the injection transformer and, subsequently, with reference to a specific case, the optimal values for the design of the device are defined. A procedure is proposed, based on simulation of the behaviour of converters, in order to calculate the operating losses of inverters controlled in accordance with the two different PWM techniques used in controlling valves of the device in question.\",\"PeriodicalId\":330283,\"journal\":{\"name\":\"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"62\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2002.1025971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2002.1025971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 62

摘要

在展示了UPQC如何能够通过不同的操作策略补偿网络电压变化之后,提出了一种这样的策略,其目的是限制设备的总损耗。根据直流电压和注入变压器的最大可注入电压的函数,对变流器的损耗程度进行了估计,随后,根据具体情况,确定了器件设计的最佳值。基于对变换器行为的模拟,提出了一种方法来计算逆变器的运行损耗,这种逆变器是根据两种不同的PWM技术控制的,这些技术用于所讨论的设备的控制阀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
UPQC compensation strategy and design aimed at reducing losses
After showing how the UPQC is able to-compensate for network voltage variations through different operating strategies, one such strategy is proposed whose aim is to limit the total losses of the device. An estimate was made of the extent of the losses of converters as a function of the DC section voltage and of the maximum injectable voltage from the injection transformer and, subsequently, with reference to a specific case, the optimal values for the design of the device are defined. A procedure is proposed, based on simulation of the behaviour of converters, in order to calculate the operating losses of inverters controlled in accordance with the two different PWM techniques used in controlling valves of the device in question.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A rotor position estimator for switched reluctance motors using CMAC A 1.5 V CCII-based tunable oscillator for portable industrial applications A practical comparison between the series-stacked and neutral point clamped converters A novel constant-frequency hysteresis current control of PFC converters Integral control technique for single-phase UPS inverter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1