P RajivN, R ArunaD, L AvinashJ, R. Jagadish, Anvi Gupta
{"title":"一种复位骨折微型假体的新方法","authors":"P RajivN, R ArunaD, L AvinashJ, R. Jagadish, Anvi Gupta","doi":"10.18231/j.jdp.2021.017","DOIUrl":null,"url":null,"abstract":"Mini implant screws are accepted world wide as it provides a stable anchorage for the various types of orthodontic tooth movements. Use of mini screw implant includes risks such as screw fracture and screw failure. With the increased use of mini implants in dentistry, there is increase in cases of mini implant fracture. Reporting and management of fractured mini implant has not been given adequate importance. We are presenting a case of successful management of fractured mini implant using ultrasonic vibrations.","PeriodicalId":379783,"journal":{"name":"The Journal of Dental Panacea","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A novel approach to retrieve fractured mini implants\",\"authors\":\"P RajivN, R ArunaD, L AvinashJ, R. Jagadish, Anvi Gupta\",\"doi\":\"10.18231/j.jdp.2021.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mini implant screws are accepted world wide as it provides a stable anchorage for the various types of orthodontic tooth movements. Use of mini screw implant includes risks such as screw fracture and screw failure. With the increased use of mini implants in dentistry, there is increase in cases of mini implant fracture. Reporting and management of fractured mini implant has not been given adequate importance. We are presenting a case of successful management of fractured mini implant using ultrasonic vibrations.\",\"PeriodicalId\":379783,\"journal\":{\"name\":\"The Journal of Dental Panacea\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Dental Panacea\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18231/j.jdp.2021.017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Dental Panacea","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/j.jdp.2021.017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A novel approach to retrieve fractured mini implants
Mini implant screws are accepted world wide as it provides a stable anchorage for the various types of orthodontic tooth movements. Use of mini screw implant includes risks such as screw fracture and screw failure. With the increased use of mini implants in dentistry, there is increase in cases of mini implant fracture. Reporting and management of fractured mini implant has not been given adequate importance. We are presenting a case of successful management of fractured mini implant using ultrasonic vibrations.