{"title":"基于模式识别算法的三相高功率因数整流器故障诊断方法","authors":"D. Foito, J. Martins, V. Pires, J. Maia","doi":"10.1109/POWERENG.2011.6036426","DOIUrl":null,"url":null,"abstract":"This paper proposes a new fault diagnosis methodology for of high power factor rectifiers. This method Is based on the combined with input line currents three dimensional space and the use of the on Principal Component Analysis (PCA). With the proposed method it is possible to detect and identify the power switch in which the fault has occurred. Such detection requires only the measurement the rectifier input currents. Simulation and experimental results are presented, considering for both healthy and faulty cases, to demonstrate the correctness of the proposed method.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"85 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Fault diagnosis method for three-phase high power factor rectifier based on a pattern recognition algorithm\",\"authors\":\"D. Foito, J. Martins, V. Pires, J. Maia\",\"doi\":\"10.1109/POWERENG.2011.6036426\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a new fault diagnosis methodology for of high power factor rectifiers. This method Is based on the combined with input line currents three dimensional space and the use of the on Principal Component Analysis (PCA). With the proposed method it is possible to detect and identify the power switch in which the fault has occurred. Such detection requires only the measurement the rectifier input currents. Simulation and experimental results are presented, considering for both healthy and faulty cases, to demonstrate the correctness of the proposed method.\",\"PeriodicalId\":166144,\"journal\":{\"name\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"85 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2011.6036426\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036426","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault diagnosis method for three-phase high power factor rectifier based on a pattern recognition algorithm
This paper proposes a new fault diagnosis methodology for of high power factor rectifiers. This method Is based on the combined with input line currents three dimensional space and the use of the on Principal Component Analysis (PCA). With the proposed method it is possible to detect and identify the power switch in which the fault has occurred. Such detection requires only the measurement the rectifier input currents. Simulation and experimental results are presented, considering for both healthy and faulty cases, to demonstrate the correctness of the proposed method.