用于微纳米尺度操作的热响应凝胶探针的研制

Masaru Takeuchi, M. Nakajima, H. Tajima, T. Fukuda
{"title":"用于微纳米尺度操作的热响应凝胶探针的研制","authors":"Masaru Takeuchi, M. Nakajima, H. Tajima, T. Fukuda","doi":"10.1109/NANO.2013.6721017","DOIUrl":null,"url":null,"abstract":"In this paper, we developed the thermoresponsive gel probe (GeT probe) to conduct micro-nano manipulation under an optical microscope. We developed the GeT probe to use in the solution which is not containing thermoresponsive polymer. The fixation force by the probe was measured using an atomic force microscope (AFM) cantilever. The evaluation of the probe showed that the probe can generate almost the same fixation force in thermoresponsive polymer solution and in the pure water. The developed GeT probe has more than 50 μm tip size and it makes difficult to handle sub-micron objects. Therefore, the new fabrication procedure to miniaturize the probe tip was also proposed to manipulate nano-scale objects. The fabrication method has the potential to minimize the probe tip in sub-micron scale.","PeriodicalId":189707,"journal":{"name":"2013 13th IEEE International Conference on Nanotechnology (IEEE-NANO 2013)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of thermoresponsive gel probe for manipulation from micro to nano scale\",\"authors\":\"Masaru Takeuchi, M. Nakajima, H. Tajima, T. Fukuda\",\"doi\":\"10.1109/NANO.2013.6721017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we developed the thermoresponsive gel probe (GeT probe) to conduct micro-nano manipulation under an optical microscope. We developed the GeT probe to use in the solution which is not containing thermoresponsive polymer. The fixation force by the probe was measured using an atomic force microscope (AFM) cantilever. The evaluation of the probe showed that the probe can generate almost the same fixation force in thermoresponsive polymer solution and in the pure water. The developed GeT probe has more than 50 μm tip size and it makes difficult to handle sub-micron objects. Therefore, the new fabrication procedure to miniaturize the probe tip was also proposed to manipulate nano-scale objects. The fabrication method has the potential to minimize the probe tip in sub-micron scale.\",\"PeriodicalId\":189707,\"journal\":{\"name\":\"2013 13th IEEE International Conference on Nanotechnology (IEEE-NANO 2013)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 13th IEEE International Conference on Nanotechnology (IEEE-NANO 2013)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NANO.2013.6721017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 13th IEEE International Conference on Nanotechnology (IEEE-NANO 2013)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NANO.2013.6721017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在本文中,我们开发了热响应凝胶探针(GeT探针),在光学显微镜下进行微纳操作。我们开发了GeT探针用于不含热敏聚合物的溶液中。探针的固定力采用原子力显微镜(AFM)悬臂测量。对探针的评价表明,探针在热敏聚合物溶液和纯水中产生的固定力几乎相同。开发的GeT探针尖端尺寸超过50 μm,很难处理亚微米物体。因此,也提出了一种新的制造工艺,使探针尖端小型化,以操纵纳米尺度的物体。该制造方法具有在亚微米尺度上使探针尖端最小化的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of thermoresponsive gel probe for manipulation from micro to nano scale
In this paper, we developed the thermoresponsive gel probe (GeT probe) to conduct micro-nano manipulation under an optical microscope. We developed the GeT probe to use in the solution which is not containing thermoresponsive polymer. The fixation force by the probe was measured using an atomic force microscope (AFM) cantilever. The evaluation of the probe showed that the probe can generate almost the same fixation force in thermoresponsive polymer solution and in the pure water. The developed GeT probe has more than 50 μm tip size and it makes difficult to handle sub-micron objects. Therefore, the new fabrication procedure to miniaturize the probe tip was also proposed to manipulate nano-scale objects. The fabrication method has the potential to minimize the probe tip in sub-micron scale.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of quantum well thermoelectric energy harvester by CMOS process ESD protection design for radio-frequency integrated circuits in nanoscale CMOS technology Optical manipulation of biological cell without measurement of cell velocity A bottom-up engineered broadband optical nanoabsorber for radiometry and energy and harnessing applications Fabrication of multilayered tube-shaped microstructures embedding cells inside microfluidic devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1