受跌落冲击的微线圈弹簧互连的预估健康监测

P. Lall, Ryan Lowe, K. Goebel
{"title":"受跌落冲击的微线圈弹簧互连的预估健康监测","authors":"P. Lall, Ryan Lowe, K. Goebel","doi":"10.1109/ICPHM.2013.6621458","DOIUrl":null,"url":null,"abstract":"In an effort to meet reliability requirements for long term human presence in space without the need for resupply, a new interconnect for grid array packages has been developed. The interconnect utilizes beryllium copper springs which are 0.05 inches in height as interconnects between the package and PCB. These novel interconnects are known as micro coil springs (MCS). The configuration is approximately the same height as copper column interconnects, but has increased compliance compared to traditional column interconnects. Because the interconnect is still in the design stage, the feasibility of integrating prognostic health management capability into the interconnect is being studied. Failure prognostics, or the prediction of impending failure for individual components, would help ensure the reliability of systems deployed on long duration space missions and provide warnings of potential failure with adequate time to formulate contingency plans. Prognostic monitoring circuitry, prediction algorithms, and performance validation are discussed for micro coil packages subjected to JDEC standard drop testing.","PeriodicalId":178906,"journal":{"name":"2013 IEEE Conference on Prognostics and Health Management (PHM)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Prognostic health monitoring for a micro-coil spring interconnect subjected to drop impacts\",\"authors\":\"P. Lall, Ryan Lowe, K. Goebel\",\"doi\":\"10.1109/ICPHM.2013.6621458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In an effort to meet reliability requirements for long term human presence in space without the need for resupply, a new interconnect for grid array packages has been developed. The interconnect utilizes beryllium copper springs which are 0.05 inches in height as interconnects between the package and PCB. These novel interconnects are known as micro coil springs (MCS). The configuration is approximately the same height as copper column interconnects, but has increased compliance compared to traditional column interconnects. Because the interconnect is still in the design stage, the feasibility of integrating prognostic health management capability into the interconnect is being studied. Failure prognostics, or the prediction of impending failure for individual components, would help ensure the reliability of systems deployed on long duration space missions and provide warnings of potential failure with adequate time to formulate contingency plans. Prognostic monitoring circuitry, prediction algorithms, and performance validation are discussed for micro coil packages subjected to JDEC standard drop testing.\",\"PeriodicalId\":178906,\"journal\":{\"name\":\"2013 IEEE Conference on Prognostics and Health Management (PHM)\",\"volume\":\"59 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Conference on Prognostics and Health Management (PHM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPHM.2013.6621458\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Conference on Prognostics and Health Management (PHM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPHM.2013.6621458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

为了满足人类在太空长期存在而不需要补给的可靠性要求,一种新的网格阵列封装互连已经开发出来。互连利用铍铜弹簧,其高度为0.05英寸作为封装和PCB之间的互连。这些新颖的互连被称为微线圈弹簧(MCS)。该配置与铜柱互连的高度大致相同,但与传统柱互连相比,具有更高的合规性。由于互连仍处于设计阶段,因此正在研究将预后健康管理功能集成到互连中的可行性。故障预测或对单个部件即将发生故障的预测,将有助于确保在长期空间任务中部署的系统的可靠性,并为制定应急计划提供足够时间的潜在故障预警。讨论了JDEC标准跌落测试中微线圈封装的预测监测电路、预测算法和性能验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prognostic health monitoring for a micro-coil spring interconnect subjected to drop impacts
In an effort to meet reliability requirements for long term human presence in space without the need for resupply, a new interconnect for grid array packages has been developed. The interconnect utilizes beryllium copper springs which are 0.05 inches in height as interconnects between the package and PCB. These novel interconnects are known as micro coil springs (MCS). The configuration is approximately the same height as copper column interconnects, but has increased compliance compared to traditional column interconnects. Because the interconnect is still in the design stage, the feasibility of integrating prognostic health management capability into the interconnect is being studied. Failure prognostics, or the prediction of impending failure for individual components, would help ensure the reliability of systems deployed on long duration space missions and provide warnings of potential failure with adequate time to formulate contingency plans. Prognostic monitoring circuitry, prediction algorithms, and performance validation are discussed for micro coil packages subjected to JDEC standard drop testing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A decentralized fault accommodation scheme for nonlinear interconnected systems A circuit-centric approach to electronic system-level diagnostics and prognostics Predictive maintenance policy optimization by discrimination of marginally distinct signals Data mining based fault isolation with FMEA rank: A case study of APU fault identification Complete parametric estimation of the Weibull model with an optimized inspection interval
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1