谐波源作用下变压器涌流分析

Chien-Lung Cheng, J. Yeh, S. Chern, Yi-Hung Lan
{"title":"谐波源作用下变压器涌流分析","authors":"Chien-Lung Cheng, J. Yeh, S. Chern, Yi-Hung Lan","doi":"10.1109/PEDS.2007.4487754","DOIUrl":null,"url":null,"abstract":"Inrush current is an important issue for three-phase transformers security and stability. It has close relationship with flux variation of three-phase transformers. Harmonic effects in power systems have been significantly increasing in the last decade. It results in more complicated for investigating inrush current. In this paper, SINm(omegat) waveforms represent non-sinusoidal waveforms because studies on SINm(omegat) waveforms appear to be simpler for more predictable results. A flux analysis of three-phase transformer for inrush current is proposed in this paper. The results are very helpful to estimate harmonics effect for inrush current.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"13 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Analysis of Transformer Inrush Current under Harmonic Source\",\"authors\":\"Chien-Lung Cheng, J. Yeh, S. Chern, Yi-Hung Lan\",\"doi\":\"10.1109/PEDS.2007.4487754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inrush current is an important issue for three-phase transformers security and stability. It has close relationship with flux variation of three-phase transformers. Harmonic effects in power systems have been significantly increasing in the last decade. It results in more complicated for investigating inrush current. In this paper, SINm(omegat) waveforms represent non-sinusoidal waveforms because studies on SINm(omegat) waveforms appear to be simpler for more predictable results. A flux analysis of three-phase transformer for inrush current is proposed in this paper. The results are very helpful to estimate harmonics effect for inrush current.\",\"PeriodicalId\":166704,\"journal\":{\"name\":\"2007 7th International Conference on Power Electronics and Drive Systems\",\"volume\":\"13 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 7th International Conference on Power Electronics and Drive Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.2007.4487754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

涌流是影响三相变压器安全稳定的重要问题。它与三相变压器的磁通变化密切相关。近十年来,电力系统中的谐波效应显著增加。这使得对励磁涌流的研究更加复杂。在本文中,SINm(omegat)波形代表非正弦波形,因为对SINm(omegat)波形的研究似乎更简单,结果更可预测。提出了一种三相变压器励磁涌流的磁通分析方法。结果对估计励磁涌流的谐波效应有很大的帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of Transformer Inrush Current under Harmonic Source
Inrush current is an important issue for three-phase transformers security and stability. It has close relationship with flux variation of three-phase transformers. Harmonic effects in power systems have been significantly increasing in the last decade. It results in more complicated for investigating inrush current. In this paper, SINm(omegat) waveforms represent non-sinusoidal waveforms because studies on SINm(omegat) waveforms appear to be simpler for more predictable results. A flux analysis of three-phase transformer for inrush current is proposed in this paper. The results are very helpful to estimate harmonics effect for inrush current.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of Multi-level Multi-domain Modeling in the Design and Analysis of a PM Transverse Flux Motor with SMC Core An Analytic Approach To Harmonic Analysis of 48-Pulse Voltage Source Inverter Combined System of Static Synchronous Series Compensation and Passive Filter applied to Wind Energy Conversion System Speed Sensorless Control with Neuron MRAS Estimator of an Induction Machine Nonlinear Decoupled Control for a Six-Phase Series-Connected Two Induction Motor Drive Using the Sliding-Mode Technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1