A. Tokuchi, N. Ninomiya, K. Yatsui, G. Imada, Q. Zhu, W. Jiang, K. Masugata
{"title":"高能感应加速器“ETIGO-III”的研制","authors":"A. Tokuchi, N. Ninomiya, K. Yatsui, G. Imada, Q. Zhu, W. Jiang, K. Masugata","doi":"10.1109/BEAMS.1998.822410","DOIUrl":null,"url":null,"abstract":"A new induction accelerator \"ETIGO-III\" has been developed to generate high current relativistic electron beam for applications in materials science, high-power microwave generation and intense X-ray generation. Using the Marx generator of \"ETIGO-I\", we have produced the initial pulse of 670 kV (60 ns pulse width). Through the four transmission lines, the pulse was fed to four induction cells. Three cores are installed inside each cell. The output voltage of 2 MV was obtained by the initial cell. Specifically, it is possible to obtain the final output parameters of 8 MeV, 5 kA 60 ns. Various diagnostics have been carried out on the characteristics of the electron beam generated by \"ETIGO-III\".","PeriodicalId":410823,"journal":{"name":"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Development of high energy induction accelerator, \\\"ETIGO-III\\\"\",\"authors\":\"A. Tokuchi, N. Ninomiya, K. Yatsui, G. Imada, Q. Zhu, W. Jiang, K. Masugata\",\"doi\":\"10.1109/BEAMS.1998.822410\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new induction accelerator \\\"ETIGO-III\\\" has been developed to generate high current relativistic electron beam for applications in materials science, high-power microwave generation and intense X-ray generation. Using the Marx generator of \\\"ETIGO-I\\\", we have produced the initial pulse of 670 kV (60 ns pulse width). Through the four transmission lines, the pulse was fed to four induction cells. Three cores are installed inside each cell. The output voltage of 2 MV was obtained by the initial cell. Specifically, it is possible to obtain the final output parameters of 8 MeV, 5 kA 60 ns. Various diagnostics have been carried out on the characteristics of the electron beam generated by \\\"ETIGO-III\\\".\",\"PeriodicalId\":410823,\"journal\":{\"name\":\"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BEAMS.1998.822410\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"12th International Conference on High-Power Particle Beams. BEAMS'98. Proceedings (Cat. No.98EX103)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BEAMS.1998.822410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
摘要
研制了一种新型感应加速器“ETIGO-III”,用于产生大电流相对论电子束,用于材料科学、高功率微波产生和强x射线产生。利用“ETIGO-I”的Marx发生器,我们产生了670 kV (60 ns脉冲宽度)的初始脉冲。通过四根传输线,脉冲被送入四个感应细胞。三个核心安装在每个单元内。初始电池的输出电压为2 MV。具体来说,可以获得8 MeV, 5 kA, 60 ns的最终输出参数。对“ETIGO-III”产生的电子束的特性进行了各种诊断。
Development of high energy induction accelerator, "ETIGO-III"
A new induction accelerator "ETIGO-III" has been developed to generate high current relativistic electron beam for applications in materials science, high-power microwave generation and intense X-ray generation. Using the Marx generator of "ETIGO-I", we have produced the initial pulse of 670 kV (60 ns pulse width). Through the four transmission lines, the pulse was fed to four induction cells. Three cores are installed inside each cell. The output voltage of 2 MV was obtained by the initial cell. Specifically, it is possible to obtain the final output parameters of 8 MeV, 5 kA 60 ns. Various diagnostics have been carried out on the characteristics of the electron beam generated by "ETIGO-III".