P. Cossoli, M. Cáceres, L. Vera, A. Firman, A. Busso
{"title":"单相并网光伏微型逆变器比例谐振控制器及LCL滤波器设计","authors":"P. Cossoli, M. Cáceres, L. Vera, A. Firman, A. Busso","doi":"10.1109/TDC-LA.2018.8511669","DOIUrl":null,"url":null,"abstract":"This paper presents a brief behavior description of LCL filters through the analysis of its frequency response and the convenience of its use instead L filters. Moreover, the equations that allow its design and implementation are also described. Regarding the Proportional Resonant (PR) controllers, their behavior, discretization techniques and digital implementation are also studies. The developed systems are evaluated by mathematical model simulation and experimental prototype test. It is concluded that, for inverters operating as a current source, the PR controllers are suitable to follow a sinusoidal reference signal. On the other hand, LCL-type filter largely eliminates the harmonic content of the output current, making it compatible for Grid-Connected PV micro-inverters.","PeriodicalId":267301,"journal":{"name":"2018 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Proportional-Resonant Controller And LCL Filter Design For Single-Phase Grid-Connected PV Micro-Inverters\",\"authors\":\"P. Cossoli, M. Cáceres, L. Vera, A. Firman, A. Busso\",\"doi\":\"10.1109/TDC-LA.2018.8511669\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a brief behavior description of LCL filters through the analysis of its frequency response and the convenience of its use instead L filters. Moreover, the equations that allow its design and implementation are also described. Regarding the Proportional Resonant (PR) controllers, their behavior, discretization techniques and digital implementation are also studies. The developed systems are evaluated by mathematical model simulation and experimental prototype test. It is concluded that, for inverters operating as a current source, the PR controllers are suitable to follow a sinusoidal reference signal. On the other hand, LCL-type filter largely eliminates the harmonic content of the output current, making it compatible for Grid-Connected PV micro-inverters.\",\"PeriodicalId\":267301,\"journal\":{\"name\":\"2018 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA)\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC-LA.2018.8511669\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D-LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC-LA.2018.8511669","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文通过分析LCL滤波器的频率响应,以及用它代替L滤波器的便利性,对LCL滤波器的性能作了简要的描述。此外,还描述了允许其设计和实现的方程。对比例谐振控制器的特性、离散化技术和数字化实现进行了研究。通过数学模型仿真和实验样机测试对所开发的系统进行了评价。结论是,对于作为电流源工作的逆变器,PR控制器适用于跟踪正弦参考信号。另一方面,lcl型滤波器在很大程度上消除了输出电流中的谐波含量,使其与并网光伏微型逆变器兼容。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Proportional-Resonant Controller And LCL Filter Design For Single-Phase Grid-Connected PV Micro-Inverters
This paper presents a brief behavior description of LCL filters through the analysis of its frequency response and the convenience of its use instead L filters. Moreover, the equations that allow its design and implementation are also described. Regarding the Proportional Resonant (PR) controllers, their behavior, discretization techniques and digital implementation are also studies. The developed systems are evaluated by mathematical model simulation and experimental prototype test. It is concluded that, for inverters operating as a current source, the PR controllers are suitable to follow a sinusoidal reference signal. On the other hand, LCL-type filter largely eliminates the harmonic content of the output current, making it compatible for Grid-Connected PV micro-inverters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Sizing of Neutral Reactors for Magnetically Controlled Shunt Reactors Connected Directly to Power Lines The Solar eclipse of August 21, 2017 in Honduras: Evidence of the impact on the power system operation Battery Energy Storage for Frequency Support in the BCS Electric Power System Optimal Distribution Systems Expansion Planning for Improving Service Restoration Planning of must-run units and optimal load shedding to maintain the security in power systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1