{"title":"酶的免疫电子显微镜,多酶复合物,和选定的其他寡聚蛋白","authors":"Heinrich Lünsdorf , Henri Tiedge","doi":"10.1016/0892-0354(92)90007-D","DOIUrl":null,"url":null,"abstract":"<div><p>The collective term “immunoelectron microscopy” subsumes a number of techniques in which the biological material is decorated with specific antibodies, prior to being visualized in the electron microscope. In this article, we have reviewed literature on immunoelectron microscopy that focusses on the analysis of the molecular architecture of proteins, in particular of enzymes and of multienzyme complexes. Molecular immunoelectron microscopy has been remarkably successful with multi-subunit enzymes of complex quaternary structures, and in many cases the data have been the basis for the eventual development of detailed three-dimensional molecular models. The elucidation of subunit composition and juxtaposition of a given enzyme, an important accomplishment in itself, has in turn stimulated and guided discussions on the catalytic mechanism; illustrative examples include F<sub>1</sub> ATPase and citrate lyase, among others. Here we have chosen a variety of enzymes, multienzyme complexes, and non-enzymatic proteins to demonstrate the versatility of immunoelectron microscopy, to illustrate methodological prerequisites and limitations, and to discuss significance and implications of individual immunoelectron microscopy studies.</p></div>","PeriodicalId":77112,"journal":{"name":"Electron microscopy reviews","volume":"5 1","pages":"Pages 105-127"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0892-0354(92)90007-D","citationCount":"1","resultStr":"{\"title\":\"Immunoelectron microscopy of enzymes, multienzyme complexes, and selected other oligomeric proteins\",\"authors\":\"Heinrich Lünsdorf , Henri Tiedge\",\"doi\":\"10.1016/0892-0354(92)90007-D\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The collective term “immunoelectron microscopy” subsumes a number of techniques in which the biological material is decorated with specific antibodies, prior to being visualized in the electron microscope. In this article, we have reviewed literature on immunoelectron microscopy that focusses on the analysis of the molecular architecture of proteins, in particular of enzymes and of multienzyme complexes. Molecular immunoelectron microscopy has been remarkably successful with multi-subunit enzymes of complex quaternary structures, and in many cases the data have been the basis for the eventual development of detailed three-dimensional molecular models. The elucidation of subunit composition and juxtaposition of a given enzyme, an important accomplishment in itself, has in turn stimulated and guided discussions on the catalytic mechanism; illustrative examples include F<sub>1</sub> ATPase and citrate lyase, among others. Here we have chosen a variety of enzymes, multienzyme complexes, and non-enzymatic proteins to demonstrate the versatility of immunoelectron microscopy, to illustrate methodological prerequisites and limitations, and to discuss significance and implications of individual immunoelectron microscopy studies.</p></div>\",\"PeriodicalId\":77112,\"journal\":{\"name\":\"Electron microscopy reviews\",\"volume\":\"5 1\",\"pages\":\"Pages 105-127\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0892-0354(92)90007-D\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electron microscopy reviews\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/089203549290007D\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electron microscopy reviews","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/089203549290007D","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Immunoelectron microscopy of enzymes, multienzyme complexes, and selected other oligomeric proteins
The collective term “immunoelectron microscopy” subsumes a number of techniques in which the biological material is decorated with specific antibodies, prior to being visualized in the electron microscope. In this article, we have reviewed literature on immunoelectron microscopy that focusses on the analysis of the molecular architecture of proteins, in particular of enzymes and of multienzyme complexes. Molecular immunoelectron microscopy has been remarkably successful with multi-subunit enzymes of complex quaternary structures, and in many cases the data have been the basis for the eventual development of detailed three-dimensional molecular models. The elucidation of subunit composition and juxtaposition of a given enzyme, an important accomplishment in itself, has in turn stimulated and guided discussions on the catalytic mechanism; illustrative examples include F1 ATPase and citrate lyase, among others. Here we have chosen a variety of enzymes, multienzyme complexes, and non-enzymatic proteins to demonstrate the versatility of immunoelectron microscopy, to illustrate methodological prerequisites and limitations, and to discuss significance and implications of individual immunoelectron microscopy studies.