在干衬里承重砌体住宅中实现气密性的新方法

D. Roberts, D. Johnston, J. Isle
{"title":"在干衬里承重砌体住宅中实现气密性的新方法","authors":"D. Roberts, D. Johnston, J. Isle","doi":"10.1191/0143624405bt116tn","DOIUrl":null,"url":null,"abstract":"This paper describes a novel approach that can be used to construct airtight drylined load-bearing masonry dwellings. This involves the application of a thin layer of ‘parging’ to the internal blockwork leaf of all external walls. Whilst this approach has so far only been undertaken on a field trial using one dwelling, the results suggest that the application of the parging layer improves the airtightness of the dwelling substantially and air leakage rates of less than 5 m3/h per m2at 50 Pa can be achieved. The paper also identifies a number of additional measures which, if undertaken, could reduce the air leakage of this dwelling even further. Practical application: Airtight construction techniques are increasingly required in order to comply with Part L of the building regulations. Wet plastering is very successful in reducing air leakage through load-bearing masonry construction but is rarely used nowadays because of its longer drying time compared with drylining. The novel approach described in this paper provides the advantages, of both systems by applying a quick-drying airtight barrier before drylining.","PeriodicalId":272488,"journal":{"name":"Building Services Engineering Research and Technology","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A novel approach to achieving airtightness in drylined load-bearing masonry dwellings\",\"authors\":\"D. Roberts, D. Johnston, J. Isle\",\"doi\":\"10.1191/0143624405bt116tn\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a novel approach that can be used to construct airtight drylined load-bearing masonry dwellings. This involves the application of a thin layer of ‘parging’ to the internal blockwork leaf of all external walls. Whilst this approach has so far only been undertaken on a field trial using one dwelling, the results suggest that the application of the parging layer improves the airtightness of the dwelling substantially and air leakage rates of less than 5 m3/h per m2at 50 Pa can be achieved. The paper also identifies a number of additional measures which, if undertaken, could reduce the air leakage of this dwelling even further. Practical application: Airtight construction techniques are increasingly required in order to comply with Part L of the building regulations. Wet plastering is very successful in reducing air leakage through load-bearing masonry construction but is rarely used nowadays because of its longer drying time compared with drylining. The novel approach described in this paper provides the advantages, of both systems by applying a quick-drying airtight barrier before drylining.\",\"PeriodicalId\":272488,\"journal\":{\"name\":\"Building Services Engineering Research and Technology\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Building Services Engineering Research and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1191/0143624405bt116tn\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Services Engineering Research and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1191/0143624405bt116tn","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文描述了一种新的方法,可用于建造气密干衬承重砌体住宅。这涉及到在所有外墙的内部木块叶片上应用一层薄薄的“parging”。虽然到目前为止,这种方法只在一个住宅中进行了现场试验,但结果表明,parging层的应用大大提高了住宅的密封性,并且可以实现在50 Pa时每平方米的空气泄漏率低于5 m3/h。本文还确定了一些额外的措施,如果采取这些措施,可以进一步减少该住宅的空气泄漏。实际应用:为了符合建筑法规的L部分,越来越需要密封施工技术。湿抹灰在减少承重砌体建筑漏风方面非常成功,但由于其干燥时间较干衬里长,目前很少使用。本文描述的新方法提供了两种系统的优点,在干燥衬里之前应用快速干燥的气密屏障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A novel approach to achieving airtightness in drylined load-bearing masonry dwellings
This paper describes a novel approach that can be used to construct airtight drylined load-bearing masonry dwellings. This involves the application of a thin layer of ‘parging’ to the internal blockwork leaf of all external walls. Whilst this approach has so far only been undertaken on a field trial using one dwelling, the results suggest that the application of the parging layer improves the airtightness of the dwelling substantially and air leakage rates of less than 5 m3/h per m2at 50 Pa can be achieved. The paper also identifies a number of additional measures which, if undertaken, could reduce the air leakage of this dwelling even further. Practical application: Airtight construction techniques are increasingly required in order to comply with Part L of the building regulations. Wet plastering is very successful in reducing air leakage through load-bearing masonry construction but is rarely used nowadays because of its longer drying time compared with drylining. The novel approach described in this paper provides the advantages, of both systems by applying a quick-drying airtight barrier before drylining.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Real coded genetic algorithm in operational optimization of a district cooling system: An inceptive applicability assessment and power saving evaluation Producing domestic energy benchmarks using a large disaggregate stock model An indoor airflow distribution predictor using machine learning for a real-time healthy building monitoring system in the tropics Producing domestic energy benchmarks using a large disaggregate stock model An indoor airflow distribution predictor using machine learning for a real-time healthy building monitoring system in the tropics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1