Leandro M Ribeiro, T. Pimenta
{"title":"脑电主动电极通信中心的实现","authors":"Leandro M Ribeiro, T. Pimenta","doi":"10.1109/ICM.2018.8704113","DOIUrl":null,"url":null,"abstract":"In order to minimize electromagnetic interferences in Electroencephalogram - EEG, we are developing an integrated circuit containing the amplifier, filter and AD converter to be placed directly over the electrodes, thus obtaining active electrodes. The active electrodes are connected to a hub that sends the data to the external equipment. Since the amplification and filtering should be programmable according to the patient and environment, the communication between the active electrodes and the external equipment (via hub) must be bidirectional. This paper describes the hub and its communication to the active electrodes using the I2C Protocol. The project was developed using the Verilog and tested on boards that emulated the hub and the active electrodes. The tests demonstrated the circuits work as expected.","PeriodicalId":305356,"journal":{"name":"2018 30th International Conference on Microelectronics (ICM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Implementation of Communication Hub for EEG Active Electrodes\",\"authors\":\"Leandro M Ribeiro, T. Pimenta\",\"doi\":\"10.1109/ICM.2018.8704113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to minimize electromagnetic interferences in Electroencephalogram - EEG, we are developing an integrated circuit containing the amplifier, filter and AD converter to be placed directly over the electrodes, thus obtaining active electrodes. The active electrodes are connected to a hub that sends the data to the external equipment. Since the amplification and filtering should be programmable according to the patient and environment, the communication between the active electrodes and the external equipment (via hub) must be bidirectional. This paper describes the hub and its communication to the active electrodes using the I2C Protocol. The project was developed using the Verilog and tested on boards that emulated the hub and the active electrodes. The tests demonstrated the circuits work as expected.\",\"PeriodicalId\":305356,\"journal\":{\"name\":\"2018 30th International Conference on Microelectronics (ICM)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 30th International Conference on Microelectronics (ICM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICM.2018.8704113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 30th International Conference on Microelectronics (ICM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICM.2018.8704113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了尽量减少脑电图中的电磁干扰,我们正在开发一种集成电路,其中包含放大器,滤波器和AD转换器,直接放置在电极上,从而获得有源电极。主动电极连接到一个集线器,该集线器将数据发送到外部设备。由于放大和滤波应根据患者和环境可编程,因此主动电极与外部设备(通过集线器)之间的通信必须是双向的。本文描述了集线器及其使用I2C协议与有源电极的通信。该项目是使用Verilog开发的,并在模拟轮毂和主动电极的电路板上进行了测试。测试表明电路工作正常。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Implementation of Communication Hub for EEG Active Electrodes
In order to minimize electromagnetic interferences in Electroencephalogram - EEG, we are developing an integrated circuit containing the amplifier, filter and AD converter to be placed directly over the electrodes, thus obtaining active electrodes. The active electrodes are connected to a hub that sends the data to the external equipment. Since the amplification and filtering should be programmable according to the patient and environment, the communication between the active electrodes and the external equipment (via hub) must be bidirectional. This paper describes the hub and its communication to the active electrodes using the I2C Protocol. The project was developed using the Verilog and tested on boards that emulated the hub and the active electrodes. The tests demonstrated the circuits work as expected.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Accelerating Deep Neural Networks Using FPGA On-body Investigation of Textile Antenna for Wearable RFID Applications Multi-Bit RRAM Transient Modelling and Analysis DEMO: Multi-Grain Adaptivity in Cyber-Physical Systems Compartive study of MPPT methods for PV systems : Case of Moroccan house
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1