在分离直流链路上平衡电容器电压的方法

D. Pappis, E. F. de Oliveira, P. Zacharias
{"title":"在分离直流链路上平衡电容器电压的方法","authors":"D. Pappis, E. F. de Oliveira, P. Zacharias","doi":"10.1109/EPE.2016.7695618","DOIUrl":null,"url":null,"abstract":"A technique to actively balance the voltages on series-connected capacitors designated to split DC sources whose loads comprise power converters is presented. It performs such balancing dynamically, enabling the voltage equalization even for small capacitors under wide power and voltages ranges. Proposal consists on lightly controlling the power of one input capacitor for each pair, measuring their voltage difference and, based upon that, generating a single control signal. Thereby, it then controls the power drained individually from that capacitor, whilst the total load remains being supplied by the whole pair. The performance of the proposed capacitor voltage balancing control loop has been demonstrated by means of experimental results of a 300 V-6 kW bipolar-buck (330 V-1500 V supply).","PeriodicalId":119358,"journal":{"name":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Method for balancing capacitors voltages on split DC-links\",\"authors\":\"D. Pappis, E. F. de Oliveira, P. Zacharias\",\"doi\":\"10.1109/EPE.2016.7695618\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A technique to actively balance the voltages on series-connected capacitors designated to split DC sources whose loads comprise power converters is presented. It performs such balancing dynamically, enabling the voltage equalization even for small capacitors under wide power and voltages ranges. Proposal consists on lightly controlling the power of one input capacitor for each pair, measuring their voltage difference and, based upon that, generating a single control signal. Thereby, it then controls the power drained individually from that capacitor, whilst the total load remains being supplied by the whole pair. The performance of the proposed capacitor voltage balancing control loop has been demonstrated by means of experimental results of a 300 V-6 kW bipolar-buck (330 V-1500 V supply).\",\"PeriodicalId\":119358,\"journal\":{\"name\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2016.7695618\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2016.7695618","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

提出了一种主动平衡负载由电源变换器组成的直流电源串联电容器电压的技术。它可以动态地实现这种平衡,甚至可以在宽功率和宽电压范围下实现小电容器的电压均衡。建议是轻微控制每一对输入电容的功率,测量它们的电压差,并在此基础上产生单个控制信号。因此,它然后控制从该电容器单独消耗的功率,而总负载仍然由整个对提供。通过300 V-6 kW双极降压电源(330 V-1500 V)的实验结果,验证了所提出的电容电压平衡控制回路的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Method for balancing capacitors voltages on split DC-links
A technique to actively balance the voltages on series-connected capacitors designated to split DC sources whose loads comprise power converters is presented. It performs such balancing dynamically, enabling the voltage equalization even for small capacitors under wide power and voltages ranges. Proposal consists on lightly controlling the power of one input capacitor for each pair, measuring their voltage difference and, based upon that, generating a single control signal. Thereby, it then controls the power drained individually from that capacitor, whilst the total load remains being supplied by the whole pair. The performance of the proposed capacitor voltage balancing control loop has been demonstrated by means of experimental results of a 300 V-6 kW bipolar-buck (330 V-1500 V supply).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Continuous control set space vector modulation for the 3×3 direct matrix converter Connector-less SiC power modules with integrated shunt — Low-profile design for low inductance and low cost DC microgrid power coordination based on fuzzy logic control Design and implementation of magnetron power supply and emulator Virtual synchronous-machine control of voltage-source converters in a low-voltage microgrid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1