二氧化硅和聚合物光纤折射传感器探头:性能评价

N. T. Venkat, Swetha Menon, D. M, A. Gowri, S. Usha, V. Sai
{"title":"二氧化硅和聚合物光纤折射传感器探头:性能评价","authors":"N. T. Venkat, Swetha Menon, D. M, A. Gowri, S. Usha, V. Sai","doi":"10.1109/WRAP54064.2022.9758357","DOIUrl":null,"url":null,"abstract":"Silica and polymeric (GOF and POF) based U-bent fiber optic sensor probes are an excellent candidate for low-cost refractive index (RI) based sensors. GOF is expensive and fragile but stable, while POF is contradictory. To evaluate the relative advantages and limitations of the GOF and POF sensor probes with respect to RI measurements, a detailed study is carried out. Measurement reproducibility and temperature stability of the RI sensor probes were investigated using a compact, hand-held fiber-optic refractometer for real-time monitoring, developed in-house. POF probes show a wider measurement range with higher deviation and poorer temperature stability with respect to GOF.","PeriodicalId":363857,"journal":{"name":"2022 Workshop on Recent Advances in Photonics (WRAP)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Silica and polymeric fiber optic refractometric sensor probes: Performance evaluation\",\"authors\":\"N. T. Venkat, Swetha Menon, D. M, A. Gowri, S. Usha, V. Sai\",\"doi\":\"10.1109/WRAP54064.2022.9758357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Silica and polymeric (GOF and POF) based U-bent fiber optic sensor probes are an excellent candidate for low-cost refractive index (RI) based sensors. GOF is expensive and fragile but stable, while POF is contradictory. To evaluate the relative advantages and limitations of the GOF and POF sensor probes with respect to RI measurements, a detailed study is carried out. Measurement reproducibility and temperature stability of the RI sensor probes were investigated using a compact, hand-held fiber-optic refractometer for real-time monitoring, developed in-house. POF probes show a wider measurement range with higher deviation and poorer temperature stability with respect to GOF.\",\"PeriodicalId\":363857,\"journal\":{\"name\":\"2022 Workshop on Recent Advances in Photonics (WRAP)\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Workshop on Recent Advances in Photonics (WRAP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WRAP54064.2022.9758357\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Workshop on Recent Advances in Photonics (WRAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WRAP54064.2022.9758357","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

基于二氧化硅和聚合物(GOF和POF)的u型弯曲光纤传感器探头是低成本折射率(RI)传感器的理想选择。GOF昂贵、脆弱但稳定,而POF则是矛盾的。为了评估GOF和POF传感器探针在RI测量方面的相对优势和局限性,进行了详细的研究。使用内部开发的紧凑型手持式光纤折射仪进行实时监测,研究了RI传感器探头的测量重复性和温度稳定性。与GOF相比,POF探头的测量范围较宽,误差较大,温度稳定性较差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Silica and polymeric fiber optic refractometric sensor probes: Performance evaluation
Silica and polymeric (GOF and POF) based U-bent fiber optic sensor probes are an excellent candidate for low-cost refractive index (RI) based sensors. GOF is expensive and fragile but stable, while POF is contradictory. To evaluate the relative advantages and limitations of the GOF and POF sensor probes with respect to RI measurements, a detailed study is carried out. Measurement reproducibility and temperature stability of the RI sensor probes were investigated using a compact, hand-held fiber-optic refractometer for real-time monitoring, developed in-house. POF probes show a wider measurement range with higher deviation and poorer temperature stability with respect to GOF.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Interplay of Modal Dispersion with Nonlinear Impairments on Mode Division Multiplexed Fibers Design and Simulation of Terahertz Wire Grid Polarizer with Sub Additional Gaps Ballistic soliton from Airy pulse Design and Optical Studies for Nanostructure Intermediate Reflector based Perovskite Silicon Tandem solar cell Terahertz Surface Plasmon Propagation in Metal Dielectric Metal Waveguide with Corrugated Surface
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1