全空气式雪地空调温湿度控制系统的基础研究(以全空气为例)控制系统)

M. Kobiyama, Airong Wang, H. Yoshinaga, K. Iijima, Yoshiomi Ito, Ryu Takahashi
{"title":"全空气式雪地空调温湿度控制系统的基础研究(以全空气为例)控制系统)","authors":"M. Kobiyama, Airong Wang, H. Yoshinaga, K. Iijima, Yoshiomi Ito, Ryu Takahashi","doi":"10.4106/JSSE.24.12","DOIUrl":null,"url":null,"abstract":"We must develop many techniques for the usage of a natural energy from the viewpoint of energy saving and keeping environment clean. In this study, we developed a simple system that could control both temperature and humidity of a general office, when we could use snow stored until summer as a cold heat source of an air-conditioner. In this report, we adopted a most simple analytical model of all air, central control and variable air volume type air-conditioner which had a blower and a single duct in order to investigate the basic characteristics, and we examined temperature and humidity analytically. As a result, the temperature of the air conditioner area could be achieved 17°C of air at the entrance and 27°C at the exit which temperatures were purposed in this analysis. However, the mean humidity of 60% could not be achieved under lower fresh air humidity than 55%, and the mean humidity became the near to the humidity of fresh air. Because this snow air-conditioning system has excellent controllable characteristics and succeeds a filter effect at the snow surface, we can hold expectation to spread this system in a snowy district widely.","PeriodicalId":199097,"journal":{"name":"Journal of Snow Engineering of Japan","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Fundamental Study on the Control System of Temperature and Humidity of All-air Type Snow Air-conditioner (In the Case of All-air I Type .ALPHA..BETA. Control System)\",\"authors\":\"M. Kobiyama, Airong Wang, H. Yoshinaga, K. Iijima, Yoshiomi Ito, Ryu Takahashi\",\"doi\":\"10.4106/JSSE.24.12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We must develop many techniques for the usage of a natural energy from the viewpoint of energy saving and keeping environment clean. In this study, we developed a simple system that could control both temperature and humidity of a general office, when we could use snow stored until summer as a cold heat source of an air-conditioner. In this report, we adopted a most simple analytical model of all air, central control and variable air volume type air-conditioner which had a blower and a single duct in order to investigate the basic characteristics, and we examined temperature and humidity analytically. As a result, the temperature of the air conditioner area could be achieved 17°C of air at the entrance and 27°C at the exit which temperatures were purposed in this analysis. However, the mean humidity of 60% could not be achieved under lower fresh air humidity than 55%, and the mean humidity became the near to the humidity of fresh air. Because this snow air-conditioning system has excellent controllable characteristics and succeeds a filter effect at the snow surface, we can hold expectation to spread this system in a snowy district widely.\",\"PeriodicalId\":199097,\"journal\":{\"name\":\"Journal of Snow Engineering of Japan\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Snow Engineering of Japan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4106/JSSE.24.12\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Snow Engineering of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4106/JSSE.24.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

从节约能源和保持环境清洁的角度出发,我们必须开发多种利用自然能源的技术。在这项研究中,我们开发了一个简单的系统,可以控制一般办公室的温度和湿度,当我们可以使用储存到夏天的雪作为空调的冷热源时。在本报告中,我们采用了最简单的全风、中央控制、变风量式空调的分析模型,其中有一个鼓风机和一个单风管来研究基本特性,并对温度和湿度进行了分析。因此,空调区域的入口温度可以达到17°C,出口温度可以达到27°C,这是本分析的目标温度。而在新风湿度低于55%的情况下,平均湿度不能达到60%,平均湿度成为新风湿度的接近值。由于该雪地空调系统具有良好的可控性,并在雪面上起到了良好的过滤作用,因此可以期待该系统在雪区得到广泛推广。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Fundamental Study on the Control System of Temperature and Humidity of All-air Type Snow Air-conditioner (In the Case of All-air I Type .ALPHA..BETA. Control System)
We must develop many techniques for the usage of a natural energy from the viewpoint of energy saving and keeping environment clean. In this study, we developed a simple system that could control both temperature and humidity of a general office, when we could use snow stored until summer as a cold heat source of an air-conditioner. In this report, we adopted a most simple analytical model of all air, central control and variable air volume type air-conditioner which had a blower and a single duct in order to investigate the basic characteristics, and we examined temperature and humidity analytically. As a result, the temperature of the air conditioner area could be achieved 17°C of air at the entrance and 27°C at the exit which temperatures were purposed in this analysis. However, the mean humidity of 60% could not be achieved under lower fresh air humidity than 55%, and the mean humidity became the near to the humidity of fresh air. Because this snow air-conditioning system has excellent controllable characteristics and succeeds a filter effect at the snow surface, we can hold expectation to spread this system in a snowy district widely.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Fundamental Study on the Control System of Temperature and Humidity of All-air Type Snow Air-conditioner (In the Case of All-air I Type .ALPHA..BETA. Control System) Simplified Heat Transfer Model of Horizontal U-Tube (HUT) System 乾燥,湿潤,氷板および圧雪路面と大気との間の熱・水蒸気移動 Horizontal U-Tube Road Heating System using Tunnel Ground Heat Perspective on Disaster Mitigation Considering Cryogenic Circumstance in Case of 2004 Niigata-ken Chuetsu Earthquake
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1