小型空气质量传感器:电化学cairpol传感器的体内测试与参考测量的比较

P. Bauerová, Zbyněk Novák, Š. Rychlík, J. Keder
{"title":"小型空气质量传感器:电化学cairpol传感器的体内测试与参考测量的比较","authors":"P. Bauerová, Zbyněk Novák, Š. Rychlík, J. Keder","doi":"10.2495/AIR180321","DOIUrl":null,"url":null,"abstract":"Use of small air quality sensors is very popular during last few years not only in research but also in public sector. From scientific point of view there are possibilities to cover larger area in air quality monitoring by adding small and easy affordable sensors into the reference measurement networks. Such an application of sensors can be very useful for identifying new hotspots or for development of finescale air quality modelling. Nevertheless, there are some limits for real-time outdoor monitoring that must be considered – higher detection limits and weak possibility to deal with non-standard conditions (low temperatures or high air humidity). Therefore, it is very important to be careful with data postprocessing and data interpretation to not get misleading air quality information. Despite a few independent studies and tests of different types of small sensors have been already done (by universities, companies and also by EU Reference Laboratories), the standardized procedure for testing and verifying the data quality has not yet been developed. Sharing the field-measurement experience with different sensors and the data correction methods is therefore crucial. Here we provide results from test measurement of set of electrochemical Cairclip sensors (Cairpol, FR) for SO2, NO2, O3/NO2 and CO during summer (in year 2015) and winter period (2017/2018). The best performance both in comparison between pairs and also between sensors and reference monitors (RM) was found out in combined O3/NO2 Cairclip sensor. Nevertheless, the association of sensor’s measured data with sum of O3 and NO2 measured by RM was much better in summer (R2 = 0.88) than in winter period (R2 = 0.31). Based on the known effect of air temperature and humidity on sensors data quality, we further applied some corrections based on dew point deficit (Td deficit). In this way verified data showed significant improvement in relationship with RM data (R2 = 0.88 with improved slope in summer and R2 = 0.58 in winter). Although the quality of sensor’s measurement can be influenced by many factors at once and further research is needed to resolve all uncertainties, the simple corrections based on the most critical meteorological factors can be very effective.","PeriodicalId":165416,"journal":{"name":"Air Pollution XXVI","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"SMALL AIR QUALITY SENSORS: IN VIVO TESTING OF ELECTROCHEMICAL CAIRPOL SENSORS IN COMPARISON TO REFERENCE MEASUREMENT\",\"authors\":\"P. Bauerová, Zbyněk Novák, Š. Rychlík, J. Keder\",\"doi\":\"10.2495/AIR180321\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Use of small air quality sensors is very popular during last few years not only in research but also in public sector. From scientific point of view there are possibilities to cover larger area in air quality monitoring by adding small and easy affordable sensors into the reference measurement networks. Such an application of sensors can be very useful for identifying new hotspots or for development of finescale air quality modelling. Nevertheless, there are some limits for real-time outdoor monitoring that must be considered – higher detection limits and weak possibility to deal with non-standard conditions (low temperatures or high air humidity). Therefore, it is very important to be careful with data postprocessing and data interpretation to not get misleading air quality information. Despite a few independent studies and tests of different types of small sensors have been already done (by universities, companies and also by EU Reference Laboratories), the standardized procedure for testing and verifying the data quality has not yet been developed. Sharing the field-measurement experience with different sensors and the data correction methods is therefore crucial. Here we provide results from test measurement of set of electrochemical Cairclip sensors (Cairpol, FR) for SO2, NO2, O3/NO2 and CO during summer (in year 2015) and winter period (2017/2018). The best performance both in comparison between pairs and also between sensors and reference monitors (RM) was found out in combined O3/NO2 Cairclip sensor. Nevertheless, the association of sensor’s measured data with sum of O3 and NO2 measured by RM was much better in summer (R2 = 0.88) than in winter period (R2 = 0.31). Based on the known effect of air temperature and humidity on sensors data quality, we further applied some corrections based on dew point deficit (Td deficit). In this way verified data showed significant improvement in relationship with RM data (R2 = 0.88 with improved slope in summer and R2 = 0.58 in winter). Although the quality of sensor’s measurement can be influenced by many factors at once and further research is needed to resolve all uncertainties, the simple corrections based on the most critical meteorological factors can be very effective.\",\"PeriodicalId\":165416,\"journal\":{\"name\":\"Air Pollution XXVI\",\"volume\":\"116 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Air Pollution XXVI\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2495/AIR180321\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Air Pollution XXVI","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/AIR180321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在过去的几年里,小型空气质量传感器的使用非常流行,不仅在研究中,而且在公共部门。从科学的角度来看,通过在参考测量网络中添加小型且易于负担得起的传感器,可以覆盖更大的空气质量监测区域。这种传感器的应用对于确定新的热点或开发精细空气质量模型非常有用。然而,室外实时监测也有一些必须考虑的限制——较高的检测限和较弱的处理非标准条件(低温或高空气湿度)的可能性。因此,在数据后处理和数据解释时要小心,以免得到误导性的空气质量信息,这一点非常重要。尽管已经对不同类型的小型传感器进行了一些独立研究和测试(由大学、公司和欧盟参考实验室进行),但尚未制定出测试和核实数据质量的标准化程序。因此,分享不同传感器的现场测量经验和数据校正方法至关重要。在这里,我们提供了一组电化学Cairclip传感器(Cairpol, FR)在夏季(2015年)和冬季(2017/2018年)对SO2, NO2, O3/NO2和CO的测试测量结果。O3/NO2组合式Cairclip传感器在对间比较和与参考监测器(RM)比较中均表现出最好的性能。然而,传感器测量数据与RM测量的O3和NO2总和的相关性在夏季(R2 = 0.88)明显好于冬季(R2 = 0.31)。在已知空气温度和湿度对传感器数据质量影响的基础上,我们进一步应用了一些基于露点亏缺(Td deficit)的校正。这样验证后的数据与RM数据的关系有显著改善(R2 = 0.88,夏季坡度改善,冬季R2 = 0.58)。虽然传感器的测量质量可能同时受到许多因素的影响,需要进一步的研究来解决所有的不确定性,但基于最关键的气象因素的简单修正是非常有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SMALL AIR QUALITY SENSORS: IN VIVO TESTING OF ELECTROCHEMICAL CAIRPOL SENSORS IN COMPARISON TO REFERENCE MEASUREMENT
Use of small air quality sensors is very popular during last few years not only in research but also in public sector. From scientific point of view there are possibilities to cover larger area in air quality monitoring by adding small and easy affordable sensors into the reference measurement networks. Such an application of sensors can be very useful for identifying new hotspots or for development of finescale air quality modelling. Nevertheless, there are some limits for real-time outdoor monitoring that must be considered – higher detection limits and weak possibility to deal with non-standard conditions (low temperatures or high air humidity). Therefore, it is very important to be careful with data postprocessing and data interpretation to not get misleading air quality information. Despite a few independent studies and tests of different types of small sensors have been already done (by universities, companies and also by EU Reference Laboratories), the standardized procedure for testing and verifying the data quality has not yet been developed. Sharing the field-measurement experience with different sensors and the data correction methods is therefore crucial. Here we provide results from test measurement of set of electrochemical Cairclip sensors (Cairpol, FR) for SO2, NO2, O3/NO2 and CO during summer (in year 2015) and winter period (2017/2018). The best performance both in comparison between pairs and also between sensors and reference monitors (RM) was found out in combined O3/NO2 Cairclip sensor. Nevertheless, the association of sensor’s measured data with sum of O3 and NO2 measured by RM was much better in summer (R2 = 0.88) than in winter period (R2 = 0.31). Based on the known effect of air temperature and humidity on sensors data quality, we further applied some corrections based on dew point deficit (Td deficit). In this way verified data showed significant improvement in relationship with RM data (R2 = 0.88 with improved slope in summer and R2 = 0.58 in winter). Although the quality of sensor’s measurement can be influenced by many factors at once and further research is needed to resolve all uncertainties, the simple corrections based on the most critical meteorological factors can be very effective.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A PRELIMINARY STUDY TO INVESTIGATE THE RELATIONSHIP BETWEEN INDOOR ENVIRONMENT AND ITS EFFECT ON PHYSICAL AND MENTAL HEALTH PROJECTING THE ENVIRONMENTAL IMPACT OF DIESEL CARS ON GASEOUS POLLUTANTS, PM2.5 AND CO2 IN A METROPOLITAN AREA FACILITATING STAKEHOLDER DIALOGUES ON A CARBON NEUTRAL CITY: WE NEED TO TALK ABOUT CARBON (AND AIR QUALITY) DETECTION AND CHARACTERIZATION OF CHEMICAL AND BIOLOGICAL AEROSOLS USING LASER-TRAPPING SINGLE-PARTICLE RAMAN SPECTROSCOPY SPATIAL HIGH-RESOLUTION MAPPING OF NATIONAL EMISSIONS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1