{"title":"电压和功率因数变化对径向和环形馈线一次配电系统功率损耗的影响","authors":"V. V. Reddy, G. Yesuratnam, M. Kalavathi","doi":"10.1109/ICETEEEM.2012.6494446","DOIUrl":null,"url":null,"abstract":"In distribution system reducing losses is an important issue during planning and operation because of its technical and economical implications. This paper presents the study of impact of variation in voltage and power factor on power loss in radial and loop type of feeders in the distribution system. The comparison is made in change in loss between radial type and closed-loop type feeders. The line losses are calculated for two different radial feeders, then the feeders are connected with tie line to form the closed loop feeder and losses are calculated. The change in the voltage profile when changed from radial to loop type is evaluated and compared. The impact of upgrading the radial system to loop system on the power loss reduction studied. Various loss reduction techniques discussed. The advantages of system running in the closed loop type over radial are studied and explored the possibility of such systems in the local area at primary distribution voltage level (33 K V). The impact on the system for this conversion is explored.","PeriodicalId":213443,"journal":{"name":"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Impact of voltage and power factor change on primary distribution feeder power loss in radial and loop type of feeders\",\"authors\":\"V. V. Reddy, G. Yesuratnam, M. Kalavathi\",\"doi\":\"10.1109/ICETEEEM.2012.6494446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In distribution system reducing losses is an important issue during planning and operation because of its technical and economical implications. This paper presents the study of impact of variation in voltage and power factor on power loss in radial and loop type of feeders in the distribution system. The comparison is made in change in loss between radial type and closed-loop type feeders. The line losses are calculated for two different radial feeders, then the feeders are connected with tie line to form the closed loop feeder and losses are calculated. The change in the voltage profile when changed from radial to loop type is evaluated and compared. The impact of upgrading the radial system to loop system on the power loss reduction studied. Various loss reduction techniques discussed. The advantages of system running in the closed loop type over radial are studied and explored the possibility of such systems in the local area at primary distribution voltage level (33 K V). The impact on the system for this conversion is explored.\",\"PeriodicalId\":213443,\"journal\":{\"name\":\"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICETEEEM.2012.6494446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETEEEM.2012.6494446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
在配电系统中,减少损耗是规划和运行中的一个重要问题,因为它具有技术和经济意义。本文研究了配电系统中电压和功率因数的变化对径向型和环状型馈线的功率损耗的影响。比较了径向馈线和闭环馈线的损耗变化。计算两种不同径向给料器的线路损耗,然后将给料器与联络线连接形成闭环给料器并计算损耗。评估和比较了从径向型到环形型电压分布的变化。研究了将径向系统升级为环形系统对降低功率损耗的影响。讨论了各种减少损耗的技术。研究了系统以闭环方式运行比径向方式运行的优点,并探讨了这种系统在一次配电电压水平(33 K V)下局部区域运行的可能性。探讨了这种转换对系统的影响。
Impact of voltage and power factor change on primary distribution feeder power loss in radial and loop type of feeders
In distribution system reducing losses is an important issue during planning and operation because of its technical and economical implications. This paper presents the study of impact of variation in voltage and power factor on power loss in radial and loop type of feeders in the distribution system. The comparison is made in change in loss between radial type and closed-loop type feeders. The line losses are calculated for two different radial feeders, then the feeders are connected with tie line to form the closed loop feeder and losses are calculated. The change in the voltage profile when changed from radial to loop type is evaluated and compared. The impact of upgrading the radial system to loop system on the power loss reduction studied. Various loss reduction techniques discussed. The advantages of system running in the closed loop type over radial are studied and explored the possibility of such systems in the local area at primary distribution voltage level (33 K V). The impact on the system for this conversion is explored.