你们的校准有多好?验尸和重新校准

J. Aguilera, B. Fisher
{"title":"你们的校准有多好?验尸和重新校准","authors":"J. Aguilera, B. Fisher","doi":"10.1109/IMTC.1990.65995","DOIUrl":null,"url":null,"abstract":"Summary form only given. It is pointed out that the standard network analyzer calibration procedure suffers from several drawbacks. The test patterns, for instance, often reside on a wafer different from that being tested. The normal procedure is to measure only a single set of calibration patterns instead of collecting a statistically significant sample spanning the wafer. Wafer thickness uniformity, for example, affects the coplanar to microstrip launch discontinuity, which impacts the quality of the calibration. The parasitic probe-to-probe capacitances also differ between the calibration and test setups. Rather than propose solutions to these and other calibration issues, the authors examine the statistical quality of measurements after calibration and test. Reciprocity and symmetry are examined for several hundred passive components from a special test wafer. The frequency-dependent deviations from perfect reciprocity and symmetry are used to evaluate the quality of the original calibration. It is shown how this information can be used to recenter the calibration and quantify the intrinsic frequency degradation.<<ETX>>","PeriodicalId":404761,"journal":{"name":"7th IEEE Conference on Instrumentation and Measurement Technology","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"How good is your calibration? A post-mortem examination and recalibration\",\"authors\":\"J. Aguilera, B. Fisher\",\"doi\":\"10.1109/IMTC.1990.65995\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary form only given. It is pointed out that the standard network analyzer calibration procedure suffers from several drawbacks. The test patterns, for instance, often reside on a wafer different from that being tested. The normal procedure is to measure only a single set of calibration patterns instead of collecting a statistically significant sample spanning the wafer. Wafer thickness uniformity, for example, affects the coplanar to microstrip launch discontinuity, which impacts the quality of the calibration. The parasitic probe-to-probe capacitances also differ between the calibration and test setups. Rather than propose solutions to these and other calibration issues, the authors examine the statistical quality of measurements after calibration and test. Reciprocity and symmetry are examined for several hundred passive components from a special test wafer. The frequency-dependent deviations from perfect reciprocity and symmetry are used to evaluate the quality of the original calibration. It is shown how this information can be used to recenter the calibration and quantify the intrinsic frequency degradation.<<ETX>>\",\"PeriodicalId\":404761,\"journal\":{\"name\":\"7th IEEE Conference on Instrumentation and Measurement Technology\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"7th IEEE Conference on Instrumentation and Measurement Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.1990.65995\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"7th IEEE Conference on Instrumentation and Measurement Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1990.65995","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

只提供摘要形式。指出标准的网络分析仪校准程序存在一些缺陷。例如,测试图案通常位于与被测试晶圆不同的晶圆上。正常的程序是只测量一组校准模式,而不是在晶圆片上收集具有统计意义的样本。例如,晶圆厚度均匀性会影响共面到微带的发射不连续,从而影响校准质量。在校准和测试设置之间,寄生探针到探针的电容也不同。而不是提出这些和其他校准问题的解决方案,作者检查校准和测试后测量的统计质量。在专用测试晶片上对数百个无源元件进行了互易性和对称性测试。利用完全互易性和对称性的频率相关偏差来评价原始校准的质量。它显示了如何使用这些信息来重新校准和量化固有频率退化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
How good is your calibration? A post-mortem examination and recalibration
Summary form only given. It is pointed out that the standard network analyzer calibration procedure suffers from several drawbacks. The test patterns, for instance, often reside on a wafer different from that being tested. The normal procedure is to measure only a single set of calibration patterns instead of collecting a statistically significant sample spanning the wafer. Wafer thickness uniformity, for example, affects the coplanar to microstrip launch discontinuity, which impacts the quality of the calibration. The parasitic probe-to-probe capacitances also differ between the calibration and test setups. Rather than propose solutions to these and other calibration issues, the authors examine the statistical quality of measurements after calibration and test. Reciprocity and symmetry are examined for several hundred passive components from a special test wafer. The frequency-dependent deviations from perfect reciprocity and symmetry are used to evaluate the quality of the original calibration. It is shown how this information can be used to recenter the calibration and quantify the intrinsic frequency degradation.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Theoretical aspects of calibration procedures in network analyzers for nonlinear one port devices The digital measurement of low values of angular velocity and acceleration MMIC related metrology at the National Institute of Standards and Technology Parameter estimation in strongly nonlinear circuits Second order discriminant function for amplitude comparison monopulse
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1