{"title":"带和不带颈圈股骨假体的应力屏蔽","authors":"H. A. Mansour, J. Ray, D. P. Mukherjee","doi":"10.1109/SBEC.1995.514429","DOIUrl":null,"url":null,"abstract":"Stress shielding in metallic implants used in total hip arthroplasty is often mentioned as the cause of loosening in many clinical cases. In this study the stress shielding was evaluated in Ti6Al4V alloy commercial femoral components with and without collar. The results from the strain gauge measurements showed that the stress shielding was lower for femoral components collar than that seen without collar.","PeriodicalId":332563,"journal":{"name":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Stress shielding of femoral component with and without collar\",\"authors\":\"H. A. Mansour, J. Ray, D. P. Mukherjee\",\"doi\":\"10.1109/SBEC.1995.514429\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stress shielding in metallic implants used in total hip arthroplasty is often mentioned as the cause of loosening in many clinical cases. In this study the stress shielding was evaluated in Ti6Al4V alloy commercial femoral components with and without collar. The results from the strain gauge measurements showed that the stress shielding was lower for femoral components collar than that seen without collar.\",\"PeriodicalId\":332563,\"journal\":{\"name\":\"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SBEC.1995.514429\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1995 Fourteenth Southern Biomedical Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBEC.1995.514429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Stress shielding of femoral component with and without collar
Stress shielding in metallic implants used in total hip arthroplasty is often mentioned as the cause of loosening in many clinical cases. In this study the stress shielding was evaluated in Ti6Al4V alloy commercial femoral components with and without collar. The results from the strain gauge measurements showed that the stress shielding was lower for femoral components collar than that seen without collar.