基于集合卡尔曼滤波的时间分辨心脏CT重建

A. George, M. Butala, R. Frazin, F. Kamalabadi, Y. Bresler
{"title":"基于集合卡尔曼滤波的时间分辨心脏CT重建","authors":"A. George, M. Butala, R. Frazin, F. Kamalabadi, Y. Bresler","doi":"10.1109/ISBI.2008.4541290","DOIUrl":null,"url":null,"abstract":"We propose an algorithm to solve the problem of Time-Resolved Cardiac Computed Tomography (CT). The algorithm reconstructs a snapshot of the moving heart at any time instant from CT projection data acquired over a single heart-cycle. The object is modeled by a spatio-temporal state-space model, and an ensemble Kalman Filter (a Monte-Carlo approximation to the Kalman filter) is used to assimilate the sequentially acquired projection data. Simulation results of the dynamic NCAT cardiac phantom, under the fan-beam geometry and a two-source CT system, show reconstructions that are free of the motion artifacts that mar conventional methods.","PeriodicalId":184204,"journal":{"name":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Time-resolved cardiac CT reconstruction using the ensemble Kalman Filter\",\"authors\":\"A. George, M. Butala, R. Frazin, F. Kamalabadi, Y. Bresler\",\"doi\":\"10.1109/ISBI.2008.4541290\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We propose an algorithm to solve the problem of Time-Resolved Cardiac Computed Tomography (CT). The algorithm reconstructs a snapshot of the moving heart at any time instant from CT projection data acquired over a single heart-cycle. The object is modeled by a spatio-temporal state-space model, and an ensemble Kalman Filter (a Monte-Carlo approximation to the Kalman filter) is used to assimilate the sequentially acquired projection data. Simulation results of the dynamic NCAT cardiac phantom, under the fan-beam geometry and a two-source CT system, show reconstructions that are free of the motion artifacts that mar conventional methods.\",\"PeriodicalId\":184204,\"journal\":{\"name\":\"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2008.4541290\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2008.4541290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

提出了一种解决时间分辨心脏计算机断层扫描(CT)问题的算法。该算法根据在单个心脏周期内获得的CT投影数据,在任意时刻重建运动心脏的快照。该方法采用时空状态空间模型对目标进行建模,并使用集合卡尔曼滤波器(一种近似卡尔曼滤波器的蒙特卡罗逼近法)对序列获取的投影数据进行同化。在扇形波束几何形状和双源CT系统下,动态NCAT心脏幻像的仿真结果显示,重建结果没有传统方法中存在的运动伪影。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Time-resolved cardiac CT reconstruction using the ensemble Kalman Filter
We propose an algorithm to solve the problem of Time-Resolved Cardiac Computed Tomography (CT). The algorithm reconstructs a snapshot of the moving heart at any time instant from CT projection data acquired over a single heart-cycle. The object is modeled by a spatio-temporal state-space model, and an ensemble Kalman Filter (a Monte-Carlo approximation to the Kalman filter) is used to assimilate the sequentially acquired projection data. Simulation results of the dynamic NCAT cardiac phantom, under the fan-beam geometry and a two-source CT system, show reconstructions that are free of the motion artifacts that mar conventional methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EEG source localization by multi-planar analytic sensing 3D general lesion segmentation in CT Automated grading of breast cancer histopathology using spectral clustering with textural and architectural image features Iterative nonlinear least squares algorithms for direct reconstruction of parametric images from dynamic PET Pathological image segmentation for neuroblastoma using the GPU
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1