{"title":"考虑电机饱和和损耗的双逆变开式永磁同步电动机驱动性能预测","authors":"Gayan Watthewaduge, M. Toulabi, S. Filizadeh","doi":"10.1109/ICELMACH.2018.8507082","DOIUrl":null,"url":null,"abstract":"In this paper, the effects of core saturation and machine's losses are considered to predict the performance of a conventional single inverter and a dual inverter open winding Interior Permanent Magnet Synchronous Motor (IPMSM) drive in Maximum Torque per Ampere (MTPA) and Field Weakening (FW) regions using Finite Element Analysis (FEA). It is shown how core saturation, which is a direct function of machine's loading, affects the d- and q-axis inductances and saliency ratio, and the losses including core, solid (due to skin and proximity effects), and mechanical losses significantly change in various operating points and may affect the operating capability of the machine in different drive configurations.","PeriodicalId":292261,"journal":{"name":"2018 XIII International Conference on Electrical Machines (ICEM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Performance Prediction of a Dual Inverter Open Winding IPMSM Drive Considering Machine's Saturation and Losses\",\"authors\":\"Gayan Watthewaduge, M. Toulabi, S. Filizadeh\",\"doi\":\"10.1109/ICELMACH.2018.8507082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the effects of core saturation and machine's losses are considered to predict the performance of a conventional single inverter and a dual inverter open winding Interior Permanent Magnet Synchronous Motor (IPMSM) drive in Maximum Torque per Ampere (MTPA) and Field Weakening (FW) regions using Finite Element Analysis (FEA). It is shown how core saturation, which is a direct function of machine's loading, affects the d- and q-axis inductances and saliency ratio, and the losses including core, solid (due to skin and proximity effects), and mechanical losses significantly change in various operating points and may affect the operating capability of the machine in different drive configurations.\",\"PeriodicalId\":292261,\"journal\":{\"name\":\"2018 XIII International Conference on Electrical Machines (ICEM)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 XIII International Conference on Electrical Machines (ICEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2018.8507082\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 XIII International Conference on Electrical Machines (ICEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2018.8507082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文考虑铁芯饱和和电机损耗的影响,利用有限元分析(FEA)预测了传统单逆变器和双逆变器开绕组内部永磁同步电动机(IPMSM)驱动在最大转矩/安培(MTPA)和磁场弱化(FW)区域的性能。结果表明,作为机器负载的直接函数,铁心饱和如何影响d轴和q轴电感和显着比,以及铁心、固体(由于表皮效应和邻近效应)和机械损耗在各个工作点上的显著变化,并可能影响机器在不同驱动配置下的运行能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance Prediction of a Dual Inverter Open Winding IPMSM Drive Considering Machine's Saturation and Losses
In this paper, the effects of core saturation and machine's losses are considered to predict the performance of a conventional single inverter and a dual inverter open winding Interior Permanent Magnet Synchronous Motor (IPMSM) drive in Maximum Torque per Ampere (MTPA) and Field Weakening (FW) regions using Finite Element Analysis (FEA). It is shown how core saturation, which is a direct function of machine's loading, affects the d- and q-axis inductances and saliency ratio, and the losses including core, solid (due to skin and proximity effects), and mechanical losses significantly change in various operating points and may affect the operating capability of the machine in different drive configurations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Fault- Tolerant PM Motors with Independent Phases by Finite Element Method Hybrid Modeling Method of Magnetic Field of Axial Flux Permanent Magnet Machine Design of Low Power Motors with a Good Compromise Between Ripple Torque and Radial Forces Joint Design of Halbach Segmented Array and Distributed Stator Winding Comparative Design Analysis of Three-Phase Switched Reluctance Generators for Micro-Wind Power Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1