{"title":"非连续毫米波工作的直流-直流稳压变换器的寄生电容对小信号频率响应的影响","authors":"Steven Embling, R. C. Wong","doi":"10.1109/PESC.1986.7415608","DOIUrl":null,"url":null,"abstract":"The presence of parasitic capacitances in the power stage of a dc-to-dc converter designed for discontinuous-mmf operation results in a ringing of the mmf during the time that the mmf is intended to be equal to zero. With a constant-frequency controller, this ringing is shown to result in a widely fluctuating small-signal loop gain for relatively small changes in operating conditions. This fluctuating loop gain, which cannot be predicted by present-day smal1-signal-modeling techniques, may result in instability if not allowed for in the design process.","PeriodicalId":164857,"journal":{"name":"1986 17th Annual IEEE Power Electronics Specialists Conference","volume":"1966 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1986-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effects of parasitic capacitances on the small-signal frequency response of a regulated dc-to-dc converter designed for discontinuous-mmf operation\",\"authors\":\"Steven Embling, R. C. Wong\",\"doi\":\"10.1109/PESC.1986.7415608\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The presence of parasitic capacitances in the power stage of a dc-to-dc converter designed for discontinuous-mmf operation results in a ringing of the mmf during the time that the mmf is intended to be equal to zero. With a constant-frequency controller, this ringing is shown to result in a widely fluctuating small-signal loop gain for relatively small changes in operating conditions. This fluctuating loop gain, which cannot be predicted by present-day smal1-signal-modeling techniques, may result in instability if not allowed for in the design process.\",\"PeriodicalId\":164857,\"journal\":{\"name\":\"1986 17th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"1966 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1986 17th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1986.7415608\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1986 17th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1986.7415608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effects of parasitic capacitances on the small-signal frequency response of a regulated dc-to-dc converter designed for discontinuous-mmf operation
The presence of parasitic capacitances in the power stage of a dc-to-dc converter designed for discontinuous-mmf operation results in a ringing of the mmf during the time that the mmf is intended to be equal to zero. With a constant-frequency controller, this ringing is shown to result in a widely fluctuating small-signal loop gain for relatively small changes in operating conditions. This fluctuating loop gain, which cannot be predicted by present-day smal1-signal-modeling techniques, may result in instability if not allowed for in the design process.