{"title":"Optimalisasi Penempatan UPFC Pada Sistem Jawa Bali 500kv Menggunakan Algoritma Genetika","authors":"Danu Firmansyah, Istiyo Winarno","doi":"10.21070/JEEE-U.V2I1.1515","DOIUrl":null,"url":null,"abstract":"The transmission network is an important part of the power system to deliver electrical energy from the power  plant to the load, therefore the power system must be maximized to achieve optimal power flow, Unified Power Flow Control (UPFC) is one of the Flexible AC Transmission System (FACTS ) capable of controlling the power of the transmission line separately on electrical transmission and can be mounted on both the sender and the receiving end of the power. The UPFC power injection model to the transmission line is made in a power flow equation. In the Java Bali (Jali) 500 kV system analyzed by the Genetic Algorithm method, to produce a power injection  that  minimizes  the  active  and  reactive power losses of the transmission line without exceeding the UPFC device limit. In the Java Bali (Jali) 500 kV system analyzed by Genetic Algorithm method, the optimum UPFC value of Reactive Power injected  to  the  system for  bus  39  is  9695.593207MVar, bus 15 is 10598.78754 MVar, and on bus 37 is10755.88608 MVar. The total loss of channel power on  the  system  prior  to  installation  of  UPFC  is1815.775809 MW, while the total loss of channel power in the system after installing UPFC with GA is1537.391648 MW.","PeriodicalId":320287,"journal":{"name":"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21070/JEEE-U.V2I1.1515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

输电网络是电力系统将电能从发电厂输送到负荷的重要组成部分,因此电力系统必须实现最优潮流,统一潮流控制(UPFC)是一种灵活的交流输电系统(FACTS),能够在电力传输中单独控制输电线路的功率,可以安装在电源的发送端和接收端。UPFC对传输线的功率注入模型建立在功率流方程中。在爪哇巴厘(Jali) 500 kV系统中,采用遗传算法方法进行分析,在不超过UPFC设备限制的情况下,产生使传输线有功功率和无功功率损耗最小的功率注入。采用遗传算法对爪哇巴厘(Jali) 500 kV系统进行分析,得到39号母线、15号母线和37号母线注入系统无功功率的最佳UPFC值分别为9695.593207MVar、10598.78754 MVar和10755.88608 MVar。安装UPFC前系统通道功率总损耗为1815.775809 MW,安装GA后系统通道功率总损耗为1537.391648 MW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimalisasi Penempatan UPFC Pada Sistem Jawa Bali 500kv Menggunakan Algoritma Genetika
The transmission network is an important part of the power system to deliver electrical energy from the power  plant to the load, therefore the power system must be maximized to achieve optimal power flow, Unified Power Flow Control (UPFC) is one of the Flexible AC Transmission System (FACTS ) capable of controlling the power of the transmission line separately on electrical transmission and can be mounted on both the sender and the receiving end of the power. The UPFC power injection model to the transmission line is made in a power flow equation. In the Java Bali (Jali) 500 kV system analyzed by the Genetic Algorithm method, to produce a power injection  that  minimizes  the  active  and  reactive power losses of the transmission line without exceeding the UPFC device limit. In the Java Bali (Jali) 500 kV system analyzed by Genetic Algorithm method, the optimum UPFC value of Reactive Power injected  to  the  system for  bus  39  is  9695.593207MVar, bus 15 is 10598.78754 MVar, and on bus 37 is10755.88608 MVar. The total loss of channel power on  the  system  prior  to  installation  of  UPFC  is1815.775809 MW, while the total loss of channel power in the system after installing UPFC with GA is1537.391648 MW.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Leak Monitoring in Split Duct Air Conditioner Based on Internet of Things Design of a Height and Weight Measurement Tool for Toddlers at Spreadsheet-Based Posyandu The Protection Relay Coordination Studies (Over Current Relays and Ground Fault Relays) On The Power Plant Electrical System, PT. Rekind Daya Mamuju By Using The ETAP 12.6 Program Design of Atmega2560 Charge Controller Battery Using Static Bicycle Sistem Monitoring Dan Kontrol Motor Listrik Industri Menggunakan Internet Of Things (IoT)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1