用于卵母细胞去核的片上磁驱动微型机器人

N. Inomata, T. Mizunuma, Y. Yamanishi, S. Kudo, F. Arai
{"title":"用于卵母细胞去核的片上磁驱动微型机器人","authors":"N. Inomata, T. Mizunuma, Y. Yamanishi, S. Kudo, F. Arai","doi":"10.1109/MHS.2009.5351824","DOIUrl":null,"url":null,"abstract":"We developed a magnetically driven microtool(MMT) used in a microfluidic chip for enucleation of oocyte. To achieve technological innovation, weight of the tool is about 1/300,000 compared with that of the conventional mechanical micromanipulator and was installed in a chip. We succeeded in precise positioning of the tool (5 μm) with low disturbances. The tool is actuated noncontact by the magnetic force, therefore, the microfluidic chip part is fully disposable with low cost. Of special notes are following. (1) Novel vibrating type of MMT is proposed to reduce the dead band of the magnetic actuation. (2) Omni-directional actuation of the tool was achieved by controlling magnetic field focused on a chip. (3) Backlash of the tool was reduced by supporting it by the flexible hinge with isotropic spring constant. (4) A polymer-metal hybrid structure which has properties of both elasticity and rigidity was employed for the tool. (5) Based on the novel and original design, we integrated a Robot-on-a-Chip (Robochip) and demonstrated on-chip enucleation of oocyte.","PeriodicalId":344667,"journal":{"name":"2009 International Symposium on Micro-NanoMechatronics and Human Science","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"On-chip magnetically driven micro-robot for enucleation of oocyte\",\"authors\":\"N. Inomata, T. Mizunuma, Y. Yamanishi, S. Kudo, F. Arai\",\"doi\":\"10.1109/MHS.2009.5351824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed a magnetically driven microtool(MMT) used in a microfluidic chip for enucleation of oocyte. To achieve technological innovation, weight of the tool is about 1/300,000 compared with that of the conventional mechanical micromanipulator and was installed in a chip. We succeeded in precise positioning of the tool (5 μm) with low disturbances. The tool is actuated noncontact by the magnetic force, therefore, the microfluidic chip part is fully disposable with low cost. Of special notes are following. (1) Novel vibrating type of MMT is proposed to reduce the dead band of the magnetic actuation. (2) Omni-directional actuation of the tool was achieved by controlling magnetic field focused on a chip. (3) Backlash of the tool was reduced by supporting it by the flexible hinge with isotropic spring constant. (4) A polymer-metal hybrid structure which has properties of both elasticity and rigidity was employed for the tool. (5) Based on the novel and original design, we integrated a Robot-on-a-Chip (Robochip) and demonstrated on-chip enucleation of oocyte.\",\"PeriodicalId\":344667,\"journal\":{\"name\":\"2009 International Symposium on Micro-NanoMechatronics and Human Science\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Symposium on Micro-NanoMechatronics and Human Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MHS.2009.5351824\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Symposium on Micro-NanoMechatronics and Human Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MHS.2009.5351824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

我们开发了一种用于卵母细胞去核微流控芯片的磁驱动微工具(MMT)。为实现技术创新,该工具重量约为传统机械微机械手的30万分之一,并安装在芯片中。我们成功地在低干扰下精确定位了刀具(5 μm)。该工具由磁力非接触驱动,因此,微流控芯片部件完全是一次性的,成本低。以下是特别说明。(1)为减小磁致动死区,提出了一种新型的振动型MMT。(2)通过控制聚焦在芯片上的磁场,实现了刀具的全方位驱动。(3)采用具有各向同性弹簧常数的柔性铰链支撑刀具,减小了刀具的间隙。(4)刀具采用兼具弹性和刚性的聚合物-金属杂化结构。(5)基于新颖的原始设计,我们集成了一个芯片上的机器人(Robochip),并演示了卵母细胞的芯片上去核。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On-chip magnetically driven micro-robot for enucleation of oocyte
We developed a magnetically driven microtool(MMT) used in a microfluidic chip for enucleation of oocyte. To achieve technological innovation, weight of the tool is about 1/300,000 compared with that of the conventional mechanical micromanipulator and was installed in a chip. We succeeded in precise positioning of the tool (5 μm) with low disturbances. The tool is actuated noncontact by the magnetic force, therefore, the microfluidic chip part is fully disposable with low cost. Of special notes are following. (1) Novel vibrating type of MMT is proposed to reduce the dead band of the magnetic actuation. (2) Omni-directional actuation of the tool was achieved by controlling magnetic field focused on a chip. (3) Backlash of the tool was reduced by supporting it by the flexible hinge with isotropic spring constant. (4) A polymer-metal hybrid structure which has properties of both elasticity and rigidity was employed for the tool. (5) Based on the novel and original design, we integrated a Robot-on-a-Chip (Robochip) and demonstrated on-chip enucleation of oocyte.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mesoscale-object handling by temperature modulation of surface stresses Three dimensional bipedal walking locomotion using dynamic passivization of joint control Wheelchair driving control with sway suppression of passenger's posture and evaluation of comfortable ride by emotional sweating Risk management system based on uncertainty estimation by multi-agent Functional shRNA expression system with reduced off-target effects
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1