M. Paulus, J. M. Rochelle, M. Andreaco, D. Binkley
{"title":"一种低噪声,宽带CMOS电荷敏感前置放大器,用于APD/LSO PET探测器","authors":"M. Paulus, J. M. Rochelle, M. Andreaco, D. Binkley","doi":"10.1109/NSSMIC.1995.504238","DOIUrl":null,"url":null,"abstract":"The recent emergence of LSO as a potential scintillator for positron emission tomography (PET) and recent improvements in avalanche photodiode (APD) technology offer encouragement that an APD/LSO based PET detector may be commercially viable in the near future. An important component of any APD/LSO based PET detector will be the preamplifier used to read out the low-level detector signals. Due to the large number of detectors (>18,000) in a high-resolution PET scanner, the preamplifier must be implemented as a monolithic integrated circuit. Additionally, in order to achieve the timing resolution required for high resolution PET, the preamplifier must have a large band-width and a low equivalent input noise voltage. This paper presents a CMOS charge-sensitive preamplifier design which uses local feedback to improve the performance of the common gate transistor. The modified cascode circuit is analyzed and compared with a previously reported simple folded cascode circuit. A prototype circuit was fabricated in a 2 /spl mu/m NWELL CMOS process. The prototype amplifier has a measured 10-90% rise-time of 7 ns with an external input capacitance of /spl sim/6 pF and has an equivalent input noise voltage of /spl sim/1.1 nV/rt-Hz above the flicker noise corner. A pulse height resolution of 14.3% FWHM and a timing resolution of 1.57 ns FWHM (vs. plastic) were obtained with the preamplifier, an Advanced Photonix 5 mm diameter beveled-edge APD and 3.5/spl times/3.5/spl times/22 mm/sup 3/ Teflon wrapped LSO crystal.","PeriodicalId":409998,"journal":{"name":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"A low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors\",\"authors\":\"M. Paulus, J. M. Rochelle, M. Andreaco, D. Binkley\",\"doi\":\"10.1109/NSSMIC.1995.504238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The recent emergence of LSO as a potential scintillator for positron emission tomography (PET) and recent improvements in avalanche photodiode (APD) technology offer encouragement that an APD/LSO based PET detector may be commercially viable in the near future. An important component of any APD/LSO based PET detector will be the preamplifier used to read out the low-level detector signals. Due to the large number of detectors (>18,000) in a high-resolution PET scanner, the preamplifier must be implemented as a monolithic integrated circuit. Additionally, in order to achieve the timing resolution required for high resolution PET, the preamplifier must have a large band-width and a low equivalent input noise voltage. This paper presents a CMOS charge-sensitive preamplifier design which uses local feedback to improve the performance of the common gate transistor. The modified cascode circuit is analyzed and compared with a previously reported simple folded cascode circuit. A prototype circuit was fabricated in a 2 /spl mu/m NWELL CMOS process. The prototype amplifier has a measured 10-90% rise-time of 7 ns with an external input capacitance of /spl sim/6 pF and has an equivalent input noise voltage of /spl sim/1.1 nV/rt-Hz above the flicker noise corner. A pulse height resolution of 14.3% FWHM and a timing resolution of 1.57 ns FWHM (vs. plastic) were obtained with the preamplifier, an Advanced Photonix 5 mm diameter beveled-edge APD and 3.5/spl times/3.5/spl times/22 mm/sup 3/ Teflon wrapped LSO crystal.\",\"PeriodicalId\":409998,\"journal\":{\"name\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1995.504238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1995.504238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors
The recent emergence of LSO as a potential scintillator for positron emission tomography (PET) and recent improvements in avalanche photodiode (APD) technology offer encouragement that an APD/LSO based PET detector may be commercially viable in the near future. An important component of any APD/LSO based PET detector will be the preamplifier used to read out the low-level detector signals. Due to the large number of detectors (>18,000) in a high-resolution PET scanner, the preamplifier must be implemented as a monolithic integrated circuit. Additionally, in order to achieve the timing resolution required for high resolution PET, the preamplifier must have a large band-width and a low equivalent input noise voltage. This paper presents a CMOS charge-sensitive preamplifier design which uses local feedback to improve the performance of the common gate transistor. The modified cascode circuit is analyzed and compared with a previously reported simple folded cascode circuit. A prototype circuit was fabricated in a 2 /spl mu/m NWELL CMOS process. The prototype amplifier has a measured 10-90% rise-time of 7 ns with an external input capacitance of /spl sim/6 pF and has an equivalent input noise voltage of /spl sim/1.1 nV/rt-Hz above the flicker noise corner. A pulse height resolution of 14.3% FWHM and a timing resolution of 1.57 ns FWHM (vs. plastic) were obtained with the preamplifier, an Advanced Photonix 5 mm diameter beveled-edge APD and 3.5/spl times/3.5/spl times/22 mm/sup 3/ Teflon wrapped LSO crystal.